11
If the overload of the device occurs (the LED warning light on the front panel is
flashing red), unwind one loop and repeat the procedure until the heating is carried
out without overload and turning off.
If the heating has a low intensity, on the contrary, try adding one loop.
6.5
Focus coil
They allow a higher intensity heating on a small area and are especially used for attaching to the
heated material.
1.
Connect the coil into the coil holder.
2.
Attach the coil on the material with the circular area of the coil.
3.
Press the button for a maximum of 10 seconds.
4.
After heating the material, let the coil cool off for at least 50 seconds.
7
Device indicators
Lights on the device indicate the following states of the device:
Green
- Standby
Yellow
- Heating in progress
Yellow flashing - Device is overheated
Red flashing - Bad coil or power overload
Red light
- Error
8
Possible problems and troubleshooting
1.
06434 is designed and constructed so that when an overload occurs, there is a temporary
turning off, which is indicated by the flashing of the LED on the front panel.
2.
The induction coils do not have any thermal protection and thus they are not protected
against overload. The operating cycle of the induction coils is set for 2 minutes of activity -
heating and 2 minutes of cooling.
3.
If the device stops working, check that it is properly connected with the electricity supply and
also check the plug connector and socket, the fuses or breaker. Check the value of the
supplied network current. Also make sure that the incoming and connection cable (if you use
it) is not damaged. Let the device cool off for at least 10 minutes and then reconnect it. If the
problem persists, contact your supplier.