SIP 05710 Скачать руководство пользователя страница 11

26 

  WIRING DIAGRAM WELDMATE T136 MIG 

11 

  ELECTRICAL CONNECTION 

WARNING! 

It  is  the  responsibility  of  the  owner  and  the  operator  to  read,  understand 

and comply with the following: 

 

You must check all electrical products, before use, to ensure that they are safe.  

You must inspect power cables, plugs, sockets and any other connectors for wear or 

damage.  

You must ensure that the risk of electric shock is minimised by the installation of appro-

priate safety devices; A residual current circuit Breaker (RCCB) should be incorporated 

in  the  main  distribution  board.  We  also  recommend  that  a  residual  current  device 

(RCD) is used. It is particularly important to use an RCD with portable products that are 

plugged into a supply which is not protected by an  RCCB. If in any doubt  consult  a 

qualified electrician.  

Connecting to the power supply: 

 

The T126 and T136 are supplied with a 13A plug pre-fitted. 

 

The  T166  is  supplied  without  a  plug  fitted,  it  must  not  be  connected  a  13A  supply, 

consult the technical specification table (page 13) for the required rating, if in doubt 

contact a qualified electrician. Before using the welder, inspect the all the leads and 

plugs to ensure that non are damaged. If any damage is visible have the welder in-

spected / repaired  by a suitably qualified person.

 

The wires for the plug are coloured in the following way: 

Yellow / green 

Earth 

Blue   

 

Neutral 

Brown  

 

Live 

As  the  colours  of  the  wires  may  not  correspond  with  the  markings  in  your  plug,  pro-

ceed as follows:  

The  wire  which  is  coloured  brown,  must  be  connected  to  the  terminal,  which  is 

marked L or coloured red.  

The wire which is coloured blue, must be connected to the terminal marked with N or 

coloured black.  

The wire which is coloured yellow / green should be connected to the terminal which 

is coloured the same or marked with this symbol 

 

 Always secure the wires in the plug terminal carefully and tightly. Secure the cable in 

the cord grip carefully. 

Содержание 05710

Страница 1: ...he packaging to the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal fac...

Страница 2: ...t No 05736 Weldmate T166 Mig SIP Part No 05756 Conforms to the requirements of the following directive s as indicated 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive 89 686 EEC Personal Pro...

Страница 3: ...anual 4 Safety Instructions 11 Electrical Connection 12 Guarantee 13 Technical Specification 14 Contents and Accessories 15 Getting to Know Your MIG Welder 19 Assembly Instructions 20 Operating Instru...

Страница 4: ...A All visitors SAFETY SYMBOLS USED THROUGHOUT THIS MANUAL SAFETY INSTRUCTIONS IMPORTANT Please read the following instructions carefully failure to do so could lead to serious personal injury and or d...

Страница 5: ...ever attempt to move the mig welder by the mains lead or pull it to remove the plug from the mains socket Keep the mains lead away from heat oil and sharp edges If the mains lead is damaged it must be...

Страница 6: ...nt protective equipment Eyes in par ticular are at risk The work must be clamped firmly whilst welding If its loose it could result in per sonal injury damage to the machine or to the item that is bei...

Страница 7: ...ammable materials must be removed from the area Have a suitable fire extinguisher available close by Causes of fire and explosion are combustibles reached by the arc flame fly ing sparks hot slag or h...

Страница 8: ...al such as electrode stubs and work pieces should never be handled without gloves First aid facilities and a qualified first aid person should be available for each shift unless medical facilities are...

Страница 9: ...rator should also wear an air supplied respirator for beryllium both must be used Metals coated with or containing materials that emit toxic fumes should not be heated unless coating is removed from t...

Страница 10: ...as those in the area use a welding mask with the correct shade filter lens CAUTION The warnings and cautions mentioned in this user manual can not cover all possible conditions and situations that may...

Страница 11: ...with a 13A plug pre fitted The T166 is supplied without a plug fitted it must not be connected a 13A supply consult the technical specification table page 13 for the required rating if in doubt conta...

Страница 12: ...se rating ELECTRICAL CONNECTION cont Guarantee This SIP MIG welder is covered by a 12 month parts and labour warranty covering fail ure due to manufacturers defects This does not cover failure due to...

Страница 13: ...ps Maximum OCV 31V AC 30V DC 32V DC Output Current Amps 60 125 Peak 30 135 Peak 30 165 Peak Output Voltage 17v 18 5v 15 5v 18v 15 5v 19 25v Wire Diameter 0 8mm 0 9mm 0 6mm 0 8mm 0 6mm 0 8mm Wire Spool...

Страница 14: ...vironment the machine should be cleaned once a month Check all connections are clean and tight if there is any oxidization clean the connection with a mild abrasive or wire brush Check all cable for d...

Страница 15: ...ls that the wire is hitting against the work then the wire speed is to high When the wire speed is correct you should get a steady crackling sound Position the torch so the mig tip is about 6mm from t...

Страница 16: ...n the roller over and refit the cover Connect the welder to a suitable electrical supply but do not switch on Remove the shroud from the torch by rotating the shroud clockwise and pulling at the same...

Страница 17: ...TING THE POLARITY T136 T166 Metal Type Wire Type Link Lead Earth Lead Gas Steel Solid CO2 or Argon CO2 Steel Gasless Flux core None Stainless Steel Solid Argon o2 Aluminium Solid Argon Note The Weldma...

Страница 18: ...d body protection Use the welding mask only for eye and face protection from sparks spatters and harmful rays from the mig welder The filter lens is not suitable for any other application or process T...