SINMAG SM-402 Mixer
W & P Reedy Pty Ltd
02-9533-9522
www.wpreedy.com.au
Page 12
Trouble Shooting:
Problem
Possible Cause
Remedy
The SINMAG
SM-402 mixer
does not start
•
Not plugged in
•
The main switch is off
•
Fuse overload at the power board
•
The mixer overload has been activated
•
Stop button still locked down
•
Safety guard open
•
Bowl and handle not raised
•
Start button not depressed
•
Plug in and switch on
•
Turn on
•
Contact supervisor
•
Resets automatically
(10 mins)
•
Release by rotating and
pulling
•
Close guard
•
Pull handle and bowl up
•
Press start button
The SINMAG
SM-402 starts
then stops
•
The mixers overload has been activated
•
Fuse overload at the power board
•
Resets automatically
(10mins). If overload
occurs repeatedly contact
supervisor or
W & P Reedy
•
Contact supervisor or
W & P Reedy
The SINMAG
SM-402
labours under
load
•
Mix too stiff / tight
•
Mechanical malfunction
•
Loose belts or drive belts
•
Review and adjust recipes
•
Advise supervisor
•
Contact W & P Reedy
service agent.
Electric motor
functions but
planetary does
not turn
•
Electrical / Mechanical malfunction
•
Switch off power at main
switch. Isolate moulder by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy
The SINMAG
SM-402 does
not stop
•
Electrical / Mechanical malfunction
•
Switch off power at main
switch. Isolate mixer by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy
Содержание SM-402
Страница 1: ...INSTRUCTION MANUAL FOR SINMAG PLANETARY MIXER SM 402 ...
Страница 20: ...SINMAG SM 402 Mixer W P Reedy Pty Ltd 02 9533 9522 www wpreedy com au Page 18 Mixer Components ...
Страница 21: ...SINMAG SM 402 Mixer W P Reedy Pty Ltd 02 9533 9522 www wpreedy com au Page 19 ...
Страница 24: ...SINMAG SM 402 Mixer W P Reedy Pty Ltd 02 9533 9522 www wpreedy com au Page 22 Electrical diagram ...