Service Manual
Original issue
May 2014
Page
26/64
Model
XL-420
| 26
Remove screw (K) and outer pipe (J). Pull down the threading lever to its lowest
position. Check and see if hook protrudes approx. 1.5mm from needle.
Loosen nut (F) under threader support shaft and turn hook portion (G) in either way for
adjustment. Tighten the nut (F) securely after adjustment.
Reassemble outer pipe (J) to correct position.
K
J
approx.1.5mm
F
G
F
G
SEC.8-4 Needle threader height (4)