Adjustment:
1.
Remove face cover.
2.
Loosen hexagonal socket screw (1) and adjust needle bar height.
3.
Tighten the screw securely after adjustment.
Check to see if needle threader operates correctly and there is not interference in vertical
movement of needle bar. Tighten the screw securely after adjustment.
SEC.7-2 Needle bar height (2)
1