SEC.5-2 Presser foot height and direction (2)
Adjustment-1
1
.
Remove the face cover, and set the feed-dog at down position.
2
.
Lower the presser foot lever.
3
.
Loosen screw (B) through hole (A) by using hexagon socket screw driver (2mm).
4
.
Tighten the screw (B) securely after checking the presser foot is parallel with the
holes for feed dog on the needle plate.
C
B
D
A