Sanitary Water Heater Technical Manual
4) Leakage of the refrigerant pipeline tested;
5) Efficient drainpipe;
6) Complete insulation protection;
7) Correct earthing;
8) Correct power supply;
9) No obstacle outside the air inlet and outlet;
10) No air in the water pipeline and all valve opened;
11) Effective electric leakage protector;
12) Sufficient inlet water pressure( 0.15MPa)
4 Refrigerant figure
System Piping figure
Model : SWH-15/190TL
Compressor:
GMCC PJ125G1C-4DZDE, R134a
E-heater:
located in the mid of tank, 3000W/230VAC;
TCO (Temp. Switch)
: when water Temp.
80, switch OFF, when water Temp.
60, switch ON;
High Pressure Switch
: switch OFF when 2.76MPa; switch ON when 2.07MPa;
Fan
: Centrifugal type, 220V—240V/50Hz 3 Speeds;
Содержание SWH-15/190TL