background image

No

Description Part 

Code 

Actualization

Qty 

Price 
Code 

1

The wind ring

201190590033

2

2

Filter

201190590030

1

3

Net

201290590058

2

4

The front cover 

201190590311

1

5

Cover

201190590039

1

6

Magnesium rod plug

201190500258

1

7

Junction box cover

201190590034

1

8

Motor

202400400568

1

9

Display panel

201190590325

1

10

Display board ass'y

201390590053

1

11

Centrifugal fan

201100100803

1

12

Display cover

201190590314

1

13

E-Part box cover

201290590061

1

14

Tank foam components

201290590208

1

14.1

Tank cover assembly

201190590322

1

14.2

Froth plug

201190500257

2

14.3

Temp sensor

202301610028

1

14.4

Magnesium anode

202990590003

1

14.5

Thermometer

202301600046

1

14.6

Stator of temp. sensor

201290590034

1

14.7

Electric heating pipe water

202403101226

1

14.8

seal ring of radiation pipe

202790590001

1

14.9

Seal Stopper

201170390002

2

14.10

Drain plug assembly

201690503031

1

14.11

Tank bottom cover

201290590067

1

14.12

PT velve loop

201190500274

5

14.13

Water tank handle

201190590042

2

14.14

Temperature and pressure safety valve

201601690004

1

15

Magnet frame

201290590057

1

16

E-part box ass'y

203390590085

1

16.1

E-part box

201290590083

1

16.2

Compressor capacitor

202401000508

1

16.3

Main control board ass'y

201390590070

1

16.4

Transformer

202300900109

1

16.5

Motor capacitor

202401190019

1

16.6

Wire joint

202301450122

3

16.7

Relay

202300800003

2

17

Electronic Control Box Bracket

201290590060

1

18

Deck board

201190590337

1

19

On the heater cover

201290590059

2

20

Deck magnet

201290501174

2

21

Magnet clip

201290501166

4

22

Magnet cover

201290501165

2

23

4-way valve ass'y

201690590198

1

23.1

Pipe joint

201601200002

1

23.3

4-way valve

201600600115

1

23.4

Solenoid

201600600212

1

24

Electronic expansion valve ass'y

201690590194

1

24.1

EEV solenoid

201601300107

1

24.2

Solenoid valve winding

201600600214

1

24.3

Electronic expansion valve

201601300524

1

24.4

Solenoid valve

201600600081

1

25

Compressor

201401500040

1

MODEL:

 

SWH

35/300TL,

 

SWH

35/300TSL

Содержание SWH-15/190TL

Страница 1: ...SERVICE MANUAL SWH 15 190TL SWH 35 300TL SWH 35 300TSL HEAT PUMP WATER HEATER...

Страница 2: ......

Страница 3: ...Sanitary Water Heater Technical Manual Applicable Model SWH 15 190TL SWH 35 300TL SWH 35 300TSL Sinclair reserves the right to discontinue or change at any time specifications or designs without noti...

Страница 4: ...urements Model Dimension mm D x H Net weight Gross weight kg Power Supply SWH 15 190TL 568 1640 96 110 220 240V 1ph 50Hz SWH 35 300TL SWH 35 300TSL 650 1 920 123 150 220 240V 1ph 50Hz External Appeara...

Страница 5: ...ating and Heat Pump heating properly made the water be heated stably and quickly 3 Flexible installation achieved by long air intake outlet duct with pressure 4 Automatic Control Automatic start up an...

Страница 6: ...em protection TCO1 TCO2 PT valve automatic defrosting over load protector temp electric leakage protector etc Air flow volume m h 414 355 312 Compressor Model PJ125G1C 4DZDE Type Rotary Brand GMCC Cap...

Страница 7: ...electric leakage protector etc Air flow m h 414 355 312 Compressor Model RB233GRDC Type Rotary Brand Guangzhou Mitsubishi electric Capacity Btu h 9500 Input kW 0 9 Fan motor Model YDK30 6R Brand well...

Страница 8: ...0 70 70 Max temp E heater 70 70 70 70 70 70 SWH 35 300TL SWH 35 300TSL Max temp Heat pump 42 47 55 60 Max temp E heater 60 60 60 60 60 60 Note Modes will be automatically selected by the unit manually...

Страница 9: ...Sanitary Water Heater Technical Manual Dimensions Model SWH 15 190TL Model SWH 35 300TL SWH 35 300TSL...

Страница 10: ...Sanitary Water Heater Technical Manual Service Space...

Страница 11: ...Sanitary Water Heater Technical Manual Wiring Diagrams Model SWH 15 190TL...

Страница 12: ...Sanitary Water Heater Technical Manual Model SWH 35 300TL SWH 35 300TSL...

Страница 13: ...Sanitary Water Heater Technical Manual Piping Diagrams...

Страница 14: ...ir outlet with canvas A 5m It is recommended to install unit by this way in the winter where there is other heat source in the room C Air inlet and outlet with duct A B 5m D Only air inlet with canvas...

Страница 15: ...r paint near the unit It may cause a fire Ask qualified person for relocating repairing and maintaining the unit instead of doing by yourself Improper installation may result in water leakage electric...

Страница 16: ...be caused Do not turn off the power supply Installation information Enough space for installation and maintenance shall be preserved The air inlet and outlet should be free from obstacles and strong w...

Страница 17: ...space of maintenance WARNING Ask your supplier to install the air source heat pump water heating units Incomplete installation performed by yourself may result in a water leakage electric shock or fir...

Страница 18: ...Sanitary Water Heater Technical Manual Unit Appearance and Composition Model SWH 15 190TL Model SWH 35 300TL...

Страница 19: ...be earthed the power cord should be connected with the external earthing line in reliable state and all the external earthing cables are effective The construction of the wiring should be carried out...

Страница 20: ...ent Please select the cable diameter according to the following methods 1 Diameter of the main line a Get from the power supply specification table according to the sum of horsepower of the unit 2 Dia...

Страница 21: ...on If the unit is used for the first time or used again after emptying the tank please make sure that the tank is full of water before turning on the power Method see figure 2 1 1 Hot water outlet Clo...

Страница 22: ...ank should be emptied Method See Figure 2 1 2 Close Open Drainpipe Open Cool water inlet Hot water outlet Close the cool water inlet open the hot drainpipe water outlet and open the nut of After empty...

Страница 23: ...will be extinguished Alarm When unit is under protection error it will flash it with 5Hz frequency as well as buzzer will sound 3 times every 1 minute until protection error eliminated or press for ca...

Страница 24: ...sign Lock indicator lights up When the unit is locked no keys can be operated 2 3 3 Clock Setting The clock is for a 24 hour system and the initial time is 00 00 To make a better use of this unit it i...

Страница 25: ...e tank Default is 55 Method for set 2 3 6 TIMER User can set up a running start time and a stop time on a specifically by the timer function The least numbers of timer is ten minutes Time on User can...

Страница 26: ...m the screen of set Temp will appear and remind user when ambience temp not meet the operation condition of heat pump unit beyond 7 43 User can switch the economy mode to E heating mode in sure of eno...

Страница 27: ...running a term E4 T3 Condenser output pipe temperature sensor error P4 Compressor overloaded protection 10 sec after compressor startup Current checking starts 1 only compressor running if it is 7A th...

Страница 28: ...r pipeline and all valve opened 11 Effective electric leakage protector 12 Sufficient inlet water pressure 0 15MPa 4 Refrigerant figure System Piping figure Model SWH 15 190TL Compressor GMCC PJ125G1C...

Страница 29: ...High Middle Low speed Fan motor will start with high speed 30s in advance of the start of compressor After staring Fan motor speed will be regulated by Tp Compressor discharge temperature with followi...

Страница 30: ...Defrosting time reaches 10 min 2 T3 15 Main components movement when defrosting 4 5 Ambient Temperature a The system s operation temperature is within 30 43 and below are the operation temperature fo...

Страница 31: ...rease while the upper part still keeps a high one and the system will start heating the lower part And it is normal Error Shooting a When common error happens the system enters Standby Mode and could...

Страница 32: ...Sanitary Water Heater Technical Manual PCB explanation PCB I O Ports description...

Страница 33: ...W2 SETTING Self checking function For the convenience of maintenance and debug query function is available by Press 2 buttons together then system running parameters will be shown one by one with foll...

Страница 34: ...lfunction 2 1 3 min Protection With the power supplied an immediate restart after the shutting down will have to wait 3 min as to protect the compressor 2 2 If self protection happens and the system s...

Страница 35: ...nect the plug Set outlet water an a higher temperature Contact the technician No hot water from the outlet Tap water has been cut away Water pressure is too low Inlet valve has been closed It ll retur...

Страница 36: ...2 20 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 14 2 15 14 3 14 4 14 5 14 6 14 7 16 14 8 17 14 9 14 10 14 11 14 12 14 13 14 14 14 15 14 16 14 17 14 18 14 19 14 20 29 28 27 26 25 23 22 21 19 18 14 21 30 30...

Страница 37: ...1190500274 2 14 16 The bottom of the coil 201690590356 1 14 17 Coil 201690590515 1 14 18 Water tank outer shell 201290590254 1 14 19 Water tank handle 201156100067 2 14 20 Sensor pipe 201290590256 1 1...

Страница 38: ......

Страница 39: ...Tank bottom cover 201290590067 1 14 12 PT velve loop 201190500274 5 14 13 Water tank handle 201190590042 2 14 14 Temperature and pressure safety valve 201601690004 1 15 Magnet frame 201290590057 1 16...

Страница 40: ...Z 202403100155 1 33 Evaporator ass y 201590590012 1 33 1 Evaporator 201590590013 1 33 2 Evaporator output pipe ass y 201690590214 1 33 3 Evaporator input pipe ass y 201690590206 1 35 Before scroll 201...

Отзывы: