28
Service Manual
9. Maintenance
9.1 Error Code List
Malfunction and Mode Display Sheet
Malfunction name
Malfunction type
Double 8
Display of indicator
Operation
indicator
Cooling
indicator
Heating
indicator
Zero-cross detection circuit malfunction
Hardware
malfunction
U8
blinks 17 times
Malfunction protection of jumper cap
Hardware
malfunction
C5
blinks 15 times
No feedback of indoor motor
Hardware
malfunction
H6
blinks 11 times
Indoor ambient temperature sensor is
open/short- circuited
Hardware
malfunction
F1
blinks 1 times
Indoor evaporator temperature sensor is
open/short-circuited
Hardware
malfunction
F2
blinks 2 times
Liquid valve temperature sensor is
open/short-circuited
Hardware
malfunction
b5
blinks 19 times
Gas valve temperature sensor is
open/short-circuited
Hardware
malfunction
b7
blinks 22 times
Module temperature sensor is
open/short-circuited
Hardware
malfunction
P7
blinks 18 times
Outdoor ambient temperature sensor is
open/short- circuited
Hardware
malfunction
F3
blinks 3 times
Outdoor condenser inlet pipe temperature
sensor is open/short- circuited
Hardware
malfunction
A5
Outdoor condenser middle pipe
temperature sensor is open/short- circuited
Hardware
malfunction
F4
blinks 4 times
Outdoor condenser outlet pipe temperature
sensor is open/short- circuited
Hardware
malfunction
A7
/
/
/
Outdoor discharge temperature sensor is
open/short- circuited
Hardware
malfunction
F5
blinks 5 times
Communication malfunction of indoor
unit and outdoor unit
Hardware
malfunction
E6
blinks 6 times
Compressor phase current circuit
detection malfunction
Hardware
malfunction
U1
blinks 12 times
Compressor demagnetization protection
Hardware
malfunction
HE
blinks 14 times
DC busbar voltage drop malfunction
Hardware
malfunction
U3
blinks 20 times
Module temperature protection
Hardware
malfunction
P8
blinks 19 times
shortage of freon or blockage protection
for the system
Hardware
malfunction
F0
blinks 10 times
Capacitor charging malfunction
Hardware
malfunction
PU
blinks 17 times
High pressure protection for the system
Hardware
malfunction
E1
blinks 1 times
Low pressure protection for the system
Hardware
malfunction
E3
blinks 3 times
Compressor blockage
Hardware
malfunction
LE
/
/
/
Drive module reset
Hardware
malfunction
P0
/
/
/
Overspeed
Hardware
malfunction
LF
/
/
/
Drive board ambient temperature sensor
malfunction
Hardware
malfunction
PF
/
/
/
AC contactor protection
Hardware
malfunction
P9
/
/
/
Содержание MV-P09BI
Страница 1: ...MULTI VARIABLE SERIES CONSOLE MV PxxBI SERVICE MANUAL EN ...
Страница 8: ...4 Service Manual 3 Outline Dimension Diagram 3 1 Indoor Unit 700 215 600 398 205 22 Unit mm ...
Страница 49: ...PARTS GUIDE MV P09BI MV P12BI MV P18BI CONSOLE MULTI VARIABLE SERIES 103 ...
Страница 50: ...MV P09BI ...
Страница 52: ...MV P12BI ...
Страница 54: ...MV P18BI ...
Страница 56: ......