39
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Steps
Procedure
1. Remove panel
Pull sliding clasps at both sides of panel,
pull out the panel outwards and then
move the panel upwards to remove it.
2. Remove filter sub-assy
Pull the damping clasps at upper/lower
side of filter sub-assy, and then move the
filter sub-assy outwards to remove it.
3. Remove front case
Remove 4 screws fixing the front case,
and then pull the front case outwards to
remove it.
panel
sliding clasps
damping clasps
filter sub-assy
screws
front case