24
Install the rear panel
1. Always mount the rear panel horizontally.
2. Fix the rear panel on the selected loca-
tion with screws supplied with the unit.
3. Be sure that the rear panel has been fixed
firmly enough to withstand the weight
of an adult of 60kg, furthermore, the
weight should be evenly shared by each
screw.
(Fig.1)
Wrenched
Bent
Flooded
Install the indoor unit
Install the connection pipes
Connect the connection pipes with the relevant union pipes of the indoor unit (Shown in P26 “Install the connec-
tion pipes”)
NOTE:
Connect the connection pipes with the indoor unit firstly and the outdoor unit secondly.
Be careful in bending the connection pipes, or you will damage the pipes.
If the tightening torque is too great in tightening the flare nuts, leakage will happen.
Electrical wiring
1. Open the surface panel.
2. Remove the wiring cover (Fig.4).
3. Route the power connection cord from the back of the indoor unit and pull it toward the front through the
wiring hole for connection.
4. Connect the blue wire of the power connection cord to the terminal “N(1)”, the brown one to “2”, the red
one to “3”, and the yellow-green one (earth wire) to “ ” as shown in Fig. 4.
5.For the heat pump type, connect the control cord to the indoor unit through wiring interface shown in Fig.4,
and clamp the connected cord on the chassis.
(Fig.2)
(Fig.3)
Install the drain hose
1. For well draining, the drain hose should be placed at a
downward slant.
2. Do not wrench or bend the drain hose or flood its end
by water.
Left piping hole
rignt piping hole
( 65)
( 65)
Install the piping hole
1. Make the piping hole ( 65) in the wall at a slight
downward slant to the outdoor side.The center of the
hole should be determined refer to Fig.1.
2.Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
66162002
6
02 11 30 10 25
24
Содержание ASH-24CN
Страница 30: ... 29 29 ...