3.Other controls
1. Memory function
Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting
Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents.
If no timer setting function in last remote control order, the system will memorize the last remote control
order, the system will memorize the last remote control order and work with last remote control setting.
In the last remote control order, there is ordinary timer function, if power off happen beffore the timer
arrived, the system will memorize the last remote control timer function, and will recalculate.
If there is timer function in last remote control order, but timer has arrive, system will run at timer on or timer
off and power off, after repowered on, the system will run at the mode before power off.
Timer function
1.Ordinary Timer setting:
Timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at
setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.
Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at
setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.
Timer setting for hour:
Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on,
when timer on has arrived, the system will run at pressetting mode.
Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on,
to set up timer off, when the timer off arrived, the system will stop to work.
Timer setting change:
When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer
also, the system will run at last setting status.
When system is running, at the same time to set up Timer on and Timer off, the system will keep the present
setting status, when time arrived, system will stop to work.
When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer
arrived, the system will start to work.
Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived,
the system will stop.
(3) Auto button
After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off.
(4) Buzzer
The controller is powered on and detect the signal received, the buzzer will beep.
(5) Sleep function
Under cooling or dehumidifying mode, the preset temperature will automatically rise by 1 , ine hour after
setting of sleep program and rise by 1 after 2hours.
Under heating mode, the preset temperature will automatically decrease by 1 one hour after setting of sleep
program and decrease by another 1 after 2hours.
Содержание ASH-18AK Series
Страница 1: ...SERVICE MANUAL KING SERIES ASH 18AK ASH 24AK ...
Страница 2: ......
Страница 9: ...Unit mm 950 700 572 378 ASH 24AK Bolt Nut Wrench over over over over ...
Страница 30: ...PARTS GUIDE ASH 18AK ASH 24AK KING SERIES ...
Страница 31: ......
Страница 32: ... 18 24 Exploded View of Components and Parts of Indoor unit ...
Страница 35: ... 18 Exploded View of Components and Parts of outdoor unit ...
Страница 37: ... 24 Exploded View of Components and Parts of outdoor unit ...