In case any obstacles exist above the outdoor unit, such obstacles must be 2000mm above the
outdoor unit.
If miscellaneous articles are piled around the outdoor unit, such articles must be 400 mm below
the top of the outdoor unit. Use 4 steel ropes of a diameter 6mm or bigger size to hoist the
outdoor unit and move it into the site.
In order to prevent scratch and deformity the outdoor unit, apply a guard board to the surface of
contact between the steel wire and the air conditioner. Remove the cushion for use in the
transport after finishing the transport.