Manual Control Mode

is indicated by the permanent illumination of a single red LED in the top of

the sensor head. 

To switch the unit back into 

Sensor Control Mode

, flick the internal wall switch/circuit breaker

off/on once within 1 second. The unit will return to 

Sensor Control Mode

.  This is indicated by the

return of the left to right scrolling LED's as described in 

Sensor Control Mode

above.

TIME CONTROL MODE - SINGLE LED FLASHING

The benefit of 

TIME CONTROL MODE

is that the user can program the unit to automatically

illuminate for a certain time, (1 - 8 hours) each night. At dusk the unit will illuminate for this set
period after which it will extinguish. The unit will then continue to operate in 

Sensor Control Mode

when it senses movement until dawn. At dusk the following night the process will be repeated, the
unit will remain on for this set period (1 - 8 hours) then operate as a PIR unit until dawn.

TIME CONTROL MODE

Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) within 3 seconds. 

A single flashing red LED at the top of the sensor head indicates Time Control Mode.  

The

unit will now illuminate for a user defined time between 1 and 8 hours. The time can be set by
rotating the centre adjustment knob as required. (See diagram G, the adjustment knob is identified
by the letter T inside a circle.)

Do not adjust this setting if you do not wish to use the Time Control Mode facility.

This time adjustment is factory set to 1 hour.
Please note: Fully anticlockwise is 1 hour, fully clockwise is 8 hours.

After the defined period has elapsed, the unit will return to 

Sensor Control Mode

and operate as

previously set up and the three scrolling LED's will illuminate from left to right.

Time Control Mode

is differento to 

Manual Control Mode

in that it will NOT reset to 

Sensor

Control Mode

at dawn, it will repeat each night until reset by the user.  To cancel 

Time Control

Mode

, switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will

turn to 

Sensor Control Mode

indicated by the scrolling LEDs.

SECTION FIVE

TECHNICAL SPECIFICATIONS

Detection Range

Detection Angle

Power Supply

Maximum Switchable Load

Lamp Type

Time On Adjustment

Dusk Level Adjustment

Environmental Protection

Up to 12 metres

200º

220 ~ 240 V AC ~ 50Hz

2000W (4 x 500W Tungsten Halogen)

230V Linear Tungsten Halogen 500W max (R7S cap)

5 seconds - 5 minutes

Day & night or night only operation

IP44 (suitable for outdoor use)

LHT0088&89 251012:lht008889.qxd  10/26/12  5:14 PM  Page 8

Содержание LHT0088

Страница 1: ...LHT0088 LHT0089 LHT0151 SECURITY FLOODLIGHT INSTALLATION MANUAL...

Страница 2: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 3: ...clause 1 is limited to replacement or repair of the Goods only at our option To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to propert...

Страница 4: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Страница 5: ...andled using a dry cloth Ensure the bulb is correctly fitted in the lampholder before use Re attach the front cover do not overtighten the fixing screw IMPORTANT Switch off the electricity at the fuse...

Страница 6: ...t to the Moon setting and Time is set to a minimum If not set as shown in diagram G Max turn knob clockwise min turn knob anticlockwise Turn the power to the unit on The lamp will illuminate for appro...

Страница 7: ...See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light level reaches the level...

Страница 8: ...illuminate for a user defined time between 1 and 8 hours The time can be set by rotating the centre adjustment knob as required See diagram G the adjustment knob is identified by the letter T inside...

Страница 9: ...switch circuit breaker off on with one second and the unit will return to Sensor Control Mode The light will illuminate only when motion is detected Sensor Control Mode is indicated by scrolling LEDs...

Страница 10: ...ess adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details The level of ambient light in the area may be too dark for the current DUSK setting D...

Страница 11: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Sensor on time control Time Control Adjuster factory set to 1 hr min...

Страница 12: ...Place this edge against wall and use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length...

Отзывы: