The unit utilises passive infrared technology to detect heat radiation of moving human bodies. 
Upon detection, the lamp will illuminate for a user-determined time period. 
An integral daylight sensor ensures night-only operation.

PARTS INCLUDED 

- Luminaire c/w PIR Sensor unit.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack.
- Tungsten halogen bulb

TOOLS & PARTS NEEDED 

- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver
- Large slotted/philips screwdriver
- Wire cutters

Unit is for outdoor use only.  Unit must be mounted on a non-flammable surface as a fixed
luminaire, and is not suitable for portable use.
The unit can get very hot during use.  Ensure the unit has cooled before handling.
Ensure adequate ventilation space is allowed between the unit and any object above, in front or
to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front.
If in any doubt, consult a qualified tradesperson or electrician.

SECTION TWO

SELECTING THE LOCATION

The motion detector has a number of detection zones, at various vertical and horizontal angles
as shown (see diagram A). 
A moving human body needs to cross/enter one of these zones to activate the sensor. The best 
all-round coverage is achieved with the unit mounted at the optimum height of 2.5m. 

Careful positioning of the sensor will be required to ensure optimum performance. See diagram A
detailing detection range and direction.

The sensor is more sensitive to movement ACROSS its field of vision than to movement directly
TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the
likely approach path.
Avoid positioning the sensor where there are any sources of heat in the detection area (extractor
fans, tumble dryer exhausts etc.). 
Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may
cause false activation under extreme conditions.

During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does
not indicate a fault with the sensor. Once normal weather conditions return, the sensor will
resume normal operation.

LHT0088&89 251012:lht008889.qxd  10/26/12  5:14 PM  Page 4

Содержание LHT0088

Страница 1: ...LHT0088 LHT0089 LHT0151 SECURITY FLOODLIGHT INSTALLATION MANUAL...

Страница 2: ...Less sensitive More sensitive TOP VIEW 200 SIDE VIEW 12m 2 5m A C B D...

Страница 3: ...clause 1 is limited to replacement or repair of the Goods only at our option To the extent permitted by law we exclude liability for a consequential loss or any other loss or damage caused to propert...

Страница 4: ...tradesperson or electrician SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body...

Страница 5: ...andled using a dry cloth Ensure the bulb is correctly fitted in the lampholder before use Re attach the front cover do not overtighten the fixing screw IMPORTANT Switch off the electricity at the fuse...

Страница 6: ...t to the Moon setting and Time is set to a minimum If not set as shown in diagram G Max turn knob clockwise min turn knob anticlockwise Turn the power to the unit on The lamp will illuminate for appro...

Страница 7: ...See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols Set the DUSK control knob fully anti clockwise Wait until darkness falls When the ambient light level reaches the level...

Страница 8: ...illuminate for a user defined time between 1 and 8 hours The time can be set by rotating the centre adjustment knob as required See diagram G the adjustment knob is identified by the letter T inside...

Страница 9: ...switch circuit breaker off on with one second and the unit will return to Sensor Control Mode The light will illuminate only when motion is detected Sensor Control Mode is indicated by scrolling LEDs...

Страница 10: ...ess adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details The level of ambient light in the area may be too dark for the current DUSK setting D...

Страница 11: ...E G F H Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Sensor on time control Time Control Adjuster factory set to 1 hr min...

Страница 12: ...Place this edge against wall and use diagram to estimate incoming cable length 75mm 3 25mm 1 INCOMING WIRE TEMPLATE Use this diagram to estimate incoming cable length...

Отзывы: