Junction details
Junction E - 2 wire to 2 wire junction
Ú
Note:
The terminal block supplied with the junction box shall not be used.
Dimensions:
70 mm
20 mm
30 mm
20 mm
Step by step instructions:
•
Slide the provided braided shield sleeve over one of
the cables
•
Remove the outer insulation of the cable according
to dimensions
•
Push back the cable´s braided shield
•
Remove insulation from the conductors
•
Connect the conductors with crimp joiners using a
professional crimp tool
•
Seal the joint with self-vulcanizing tape
•
Pull the braided shields over the joint
•
Pull the provided braided shield sleeve over the
joint
•
Seal the joint with self-vulcanizing tape
•
The joint is now ready to be sealed in the junction
box. Refer to
"Junction box assembly"
on page 32