Page 4-12
Robertson AP45 Autopilot
Technical specifications
Simrad Robertson AS
Egersund - Norway
Dimensions:................................................ See Fig. 4-15.
Supply voltage:........................................... 24/32V DC ±20%
Current consumption:................................ Maximum 100 mA
Input signal: ................................................. Voltage (0-18V) or
current (0.1 - 1.1mA)
Rudder angle: .............................................45°-0-45° (other angles as option)
Ambient temperature, storage: ............–25 - +70°C
operation: ........–10 - +55°C
Protection:...................................................IP56
Safe distance to magnetic compass: ..........2.6 m (9 ft.)
Rudder Feedback Units:
RF45X, RF14XU, RF14XI.
13
7
(
5
.4
0"
)
14
4 (
5
.6
7"
)
Panel cut-out:138x138 (5.44")
65 (2.56")
57 (2.24")
144 (5.67")
15
3 (
6
.02"
)
RI9
Fig. 4-15
RI9 Rudder Angle Indicator - Dimensions
RI9 Rudder Angle
Indicator
Содержание ROBERTSON AP45
Страница 1: ...INSTRUCTION MANUAL Robertson AP45 Autopilot 20220042 6 02...
Страница 2: ...This page is intentionally left blank...
Страница 6: ...Robertson AP45 Modification record Simrad Robertson AS Egersund Norway...
Страница 32: ...Page 2 18 Robertson AP45 Autopilot Operation Simrad Robertson AS Egersund Norway...
Страница 66: ...Page 5 16 Robertson AP45 Autopilot Installation Simrad Robertson AS Egersund Norway...
Страница 88: ...Page 5 38 Robertson AP45 Autopilot Installation Simrad Robertson AS Egersund Norway...
Страница 96: ...Page 6 8 Robertson AP45 Autopilot Start Up procedure Commissioning Simrad Robertson AS Egersund Norway...
Страница 122: ...Page 8 18 Robertson AP45 Autopilot Spare parts and drawings Simrad Robertson AS Egersund Norway...