Simrad PI32
48
857-164636 / Rev.A
How to set up the sensors
The very first time you switch on the PI32, you will need to set
up the sensor configuration. This will also be required if you
perform a “master reset” on the PI32, and then reload the
manufacturer’s default settings.
Observe the following procedure to establish the most common
values. For more detailed information about the settings, refer to
the
References
chapter.
Note:
In order to establish the sensor configuration, you need to know
what kind of sensors you have, which channels they
communicate on, and how often they communicate. This
information is required before you start the configuration on the
PI32.
Note:
Do not attempt to set up the sensors unless this is absolutely
necessary.
We strongly suggest that you use the forms in the front of this
manual to write down the sensor you have with information
about their update rates and communication channels.
1
Press the
MENU
button to open the main menu.
2
Open the
Setup
menu, and select
Sensor setup
.
3
Press the
ENT
button to enable modification. Observe the
warning, and press the
ENT
button to proceed.
- In the following, you must use the
Selector pad
to
navigate through the parameters, and the
+
and
-
buttons to select values.
- Each of the three sensors are initially set to
None
and
Normal
, and the communication channels are not
defined.
4
For
Sensor 1
:
a
Set type (currently
None
) to
Single
.
b
Set
Update
to the current update rate of the chosen
sensor (Slow, Normal or Fast)
c
Set
Measure
to the type of sensor.
d
Select transmission
Channel
(currently
NO
), and use
the
+
and
-
buttons to select desired channel.
5
Repeat for
Sensor 2
and
Sensor 3
.
6
Press the
ENT
button to save the configuration and exit.