System configuration
Sensor configuration:
The sensor must be configured with a
unique sensor number. Select channel number according to the
sensor’s configuration. Write down the configuration for future
reference.
Status & Receiver:
The Interference filter must be switched on.
Set it to level 9 if you have noise problems from other
hydroacoustic sources. Note that with the filter on, it will
influence the signal spectrum shown in the
Status display
.
Sensor filter:
Switch this filter to
Light
. Set it to
Heavy
only if
you experience excessive noise. Position
Off
will provide raw
data and fastest possible response.