Simrad GC80/85 Dual MK2 Gyro Compass
988-12720-002
136
13.3
Complete alarm code list
Alarm
code
Alarm content
Detailed
code
Possible cause
E-1
Main power is
abnormal
1
Main power (AC power source) is lost.
E-2
Power is abnormal
2
Power supply unit in the control box becomes over current.
3
Power supply unit in the control box becomes over voltage.
4
24R is lost.
E-3
Inverter is
abnormal
5
Inverter in the Master compass becomes over current.
6
Inverter in the Master compass becomes over voltage.
E-4 *1
Control power is
abnormal
7
+12.5 V is abnormal.
8
-12.5 V is abnormal.
9
+10 V is abnormal.
10
-10 V is abnormal.
E-5 *1
Rotor current is
abnormal
11
Gyro rotor current is abnormal.
E-6
Rotor tilting angle
is abnormal
12
Rotor tilting angle is abnormal.
E-7 *1
Servo loop is
abnormal
13
Horizontal servo loop is abnormal.
14
Bearing servo loop is abnormal.
15
Rate limit is abnormal.
E-8
Zero cross is
abnormal
36
Zero cross azimuth angle sensor is abnormal.
E-9 *1
Memory is
abnormal
16
Memory is abnormal
17
18
19
20
E-A
Communication
error (1)
21
Communication error (MCC
→
SCC).
23
MCC is reset.
E-b *1
Communication
error (2)
22
Communication error (SCC
→
MCC).
24
SCC is reset.
E-c
GPS
communication off
25
GPS system is stopped or serial signal from GPS is cut
(timeout is 15 sec).
E-d
GPS data abnormal
26
GPS latitude data abnormal (timeout is 17 sec).
27
GPS speed data abnormal (timeout is 17 sec).
E-E
MAG/EHS
communication off
32
MAG/EHS system is stopped or serial signal from GPS is cut
(timeout is 15 sec).
Содержание GC80 Compact MK2
Страница 1: ...ENGLISH GC80 85 Dual MK2 User Manual www navico commercial com...
Страница 2: ......
Страница 4: ...Simrad GC80 85 Dual MK2 Gyro Compass iii 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 5: ...PREFACE 988 12720 002 iv 1 PREFACE...
Страница 14: ...Simrad GC80 85 Dual MK2 Gyro Compass xiii 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 19: ...SYSTEM OVERVIEW 5 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 25: ...USER INTERFACE 11 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 42: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 28 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 55: ...INSTALLATION 41 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 67: ...INSTALLATION 53 988 12720 002 PCC board No external sensor Active external sensor...
Страница 70: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 56 Pendulum switch disabled Pendulum switch enabled...
Страница 83: ...INSTALLATION 69 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 91: ...ADVANCED SETTINGS 77 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 100: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 86 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 103: ...DRAWINGS 89 988 12720 002 Simrad Egersund AS NORWAY EGERSUND GC80 GC85 Dimensions Dual Control unit 1 3 N 1 710189 A...
Страница 105: ...DRAWINGS 91 988 12720 002...
Страница 106: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 92...
Страница 107: ...DRAWINGS 93 988 12720 002...
Страница 108: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 94...
Страница 109: ...DRAWINGS 95 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ...SPARE PART LIST 99 988 12720 002 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 126: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 112 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 143: ...DIP SWITCH SETTINGS 129 988 12720 002 12 6 PCC board...
Страница 146: ...Simrad GC80 85 Dual MK2 Gyro Compass 988 12720 002 132 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 155: ......
Страница 156: ...988 12720 002...