GAIN-
83 output
GAIN+
►
Unit description: ECHO SOUNDER
Device instance 000
System instance 000
MENU
Exit Accept
ENT
∆
∆
Identification
Chapter 10-12
EQ44/54 SETUP menu
For instance, if the SimNet cable is pulled, the counter will be acti-
vated and once the cable is back in place, the counter will stop, but
will stay at the figure it has reached. So therefore, a figure other than
0 does not necessarily mean that something is wrong, only if the
figure continues to increase.
Prior to call for technical assistance:
1. Check connected cabling.
2. Check supply voltage to be between 10.8-15 VDC to the SimNet
system.
3. Systematically disconnect one unit at a time to see which one is
causing the problem. Start at the opposite end of the 12V power
supply.
The two last lines in the SimNet diagnostic interface are for techni-
cians only.
GAIN+
Go to the next interface
- step back with [GAIN-]
The interfaces: SimNet input, SimNet output, NMEA0183 input and
NMEA0183 output are for technicians only.
GAIN+
Go to the next and last interface: Identification
- step back with [GAIN-]
Unit description
- can be customized to read e.g. BACK-UP UNIT.
Maximum number of characters is 16.
The identification name can be seen in the Nodes interface - refer to
the beginning of this section.
ENT
Confirm editing, or...
Содержание EQ44
Страница 1: ...M A N U A L Simrad EQ44 54 Echosounder 183 3403 102 English 05082 20...
Страница 2: ......
Страница 6: ...Table of contents EQ44 54 Echosounder...
Страница 12: ...Chapter 1 6 EQ44 54 Introduction and safety summary...
Страница 26: ...Chapter 3 6 EQ44 54 Echosounder operation...
Страница 68: ...Chapter 10 18 EQ44 54 SETUP menu...
Страница 70: ...Chapter 11 2 EQ44 54 Installation and service Other important settings...
Страница 76: ...AT44 Chapter 11 8 EQ44 54 Installation and service 11 5 Electrical connections...
Страница 77: ...EQ44 54 Installation and service Chapter 11 9...
Страница 97: ...EQ44 54 Echosounder Index...