Chapter 4-6
EQ44/54 STND menu
Range
– refers to the distance shown from the top to the bottom of
the display screen. Selecting
Auto range
will cause the EQXX to
change the basic range setting(s) to keep the displayed bottom in
the lower half of the display. For instance, as your boat moves into
deeper waters, the system will automatically switch to a deeper
range, always keeping the displayed bottom in the lower half of the
display.
Manual range
allows the operator to set the range displayed
on the screen.
Gain
– is another way of saying “sensitivity”, or possibly “volume”.
Increasing the gain setting of the EQXX will allow you to see
smaller and deeper targets. If the gain is set too high, however, you
will begin to see “noise” and unwanted targets. Generally speaking,
you want to set the gain control just below the point that you begin
to see speckles of “noise” between surface and the bottom on the
screen.
White line
– is a control which places a white/black line at the
displayed sea floor and blanks out 4 pixels just below the line. The
purpose of this is to help the user detect targets, such as fish, which
are very close to the sea floor and whose echoes tend to merge with
those of the sea floor itself.
Expansion window (zoom level)
- can be selected in eight steps,
ranging from 1 to 50 meters, or converted to feet or fathoms (refer
to Setup for units, section 10.3). This function allows you to take a
closer look at a particular section of the water underneath your boat.
You can expand the view near the bottom (Bottom expansion) or
near the Variable Range Marker (VRM expansion).
TVG
– Time Varying Gain – is a control that allows the EQXX to
make corrections for most of the losses and absorption that occurs as
sound energy passes through sea water. There are three settings to
choose from, Normal, Special and OFF.
The setting “Normal (20 log R)” is for general fish finding at depths
down to 50m (150’) and it will also give a uniform bottom echo pres-
entation at shallow, mid and deep water.
The setting “Special (40 log R)” will adjust the TVG to show the
same echo strength for a given size fish at varying depths.
The OFF position is used for net sounders. In OFF position the TVG
is inactive which means that the sounder operates with a fixed gain
between each transmitter pulse. Auto range is switched to manual.
Содержание EQ44
Страница 1: ...M A N U A L Simrad EQ44 54 Echosounder 183 3403 102 English 05082 20...
Страница 2: ......
Страница 6: ...Table of contents EQ44 54 Echosounder...
Страница 12: ...Chapter 1 6 EQ44 54 Introduction and safety summary...
Страница 26: ...Chapter 3 6 EQ44 54 Echosounder operation...
Страница 68: ...Chapter 10 18 EQ44 54 SETUP menu...
Страница 70: ...Chapter 11 2 EQ44 54 Installation and service Other important settings...
Страница 76: ...AT44 Chapter 11 8 EQ44 54 Installation and service 11 5 Electrical connections...
Страница 77: ...EQ44 54 Installation and service Chapter 11 9...
Страница 97: ...EQ44 54 Echosounder Index...