background image

| 3

Contents | 

E5024 ECDIS Installation Manual

Contents

E5024 System overview

E5000 CPU

Hardware installation

Mounting location

E5000 processor installation

M570 trackball

M5024 series monitor installation

E0102 Alarm panel and SI80

LTSX50 trackball (Option)

9 Wiring

9 Guidelines

Power connection

10 

External alarm

12 

Connecting control devices

12 

The CAN bus

14 

NMEA 0183 device connection

15 

Ethernet device connection

16  Getting ready to use the system

16 

Installing the charts from the NavStick

18 

Installing charts from other suppliers

18 

Selecting charts to display

19  ECDIS Software setup

19 

Chart settings

19 

Vessel settings

23 

Websocket interface connection

25 

AIS settings

25 

Radar targets settings

26 

Radar settings

27 

System settings

30 

Alarms settings

33  Installation approval

33 

Mechanical Installation

33 

Power connection

33 

External equipment

34  Spare parts and accessories 

34 

E5024 ECDIS system

34 

NSO evo2 accessories

35 

Ethernet cables

36  Supported data

36 

ECDIS NMEA 0183 & NMEA 2000 supported sentences

38  E5000 Processor specifications

39  Dimensional drawings

39 

E5000 Dimensional drawings

39 

LTSX50N8 trackball dimensional drawings

Содержание E5024 ECDIS

Страница 1: ...ENGLISH E5024ECDISSystem Installation Manual...

Страница 2: ......

Страница 3: ...e of any queries refer to the brand web site of your display or system http pro simrad yachting com Declarations and conformance This equipment is intended for use in international waters as well as c...

Страница 4: ...t and receiver Connect the equipment into an outlet on a circuit different from that of the receiver Consult the dealer or an experienced technician for help Trademarks NMEA 2000 is a registered trade...

Страница 5: ...g the charts from the NavStick 18 Installing charts from other suppliers 18 Selecting charts to display 19 ECDIS Software setup 19 Chart settings 19 Vessel settings 23 Websocket interface connection 2...

Страница 6: ...g video from a variety of sources M5024 monitors are color calibrated according to ECDIS requirements For installation and setup refer to the M5000 Series User Manual Separate documents are delivered...

Страница 7: ...I S s y s t e m I n s t a l l a t i o n M a n u a l s im ra d y a c h ti n g c o m EN G LI SH E 5 0 2 4 E C D I S s y s t e m I n s t a l l a t i o n M a n u a l s im ra d y a c h ti n g c o m Item D...

Страница 8: ...d 7 USB ports 2 n a 8 HDMI sockets 1 1 9 SD card slot 1 port shared Note For NSO evo2 Installation refer to the separate NSO evo2 Installation Manual Note On the E5000 hardware there are some differen...

Страница 9: ...ee E5000 Dimensional drawings on page 39 Warning When installing ensure appropriate safety equipment is used e g ear muffs protective glasses gloves and a dust mask Power tools may exceed safe noise l...

Страница 10: ...1 The remote power signal is required to be used for a compliant ECDIS system It is recommended that the remote power signal wire be connected to the main bridge or conning station power circuit This...

Страница 11: ...he installation fire electrical shock or other serious injury may occur Warning Ensure that the voltage of the power supply is compatible with the E5000 Processor Warning The positive supply wire red...

Страница 12: ...e wire to GND O V 1 2 4 5 6 3 24 V NEG 24 V NEG SIMRAD ALARM RESET 1 E5000 processor 2 Powerplug E5000 3 Main power E5000 4 E0102 Alarm panel 5 Blue alarm pin E5000 6 E0102 separate power For wiring d...

Страница 13: ...specifications on page 38 Note LCD monitors intended for home office use are not designed to operate in areas exposed to direct sunlight and will appear dark and difficult to read Also unless carefull...

Страница 14: ...via adaptor cables A network consists of a linear backbone from which drop cables connect to the CAN bus compliant devices A single drop cable has a maximum length of 6 m 19 7 ft The total length of...

Страница 15: ...drop of the network If an SI80 unit is included in the system this unit should be used for powering the CAN bus backbone Note Do not connect the CAN bus power cable to the same terminals as the engin...

Страница 16: ...ite NMEA 0183 RX_A NMEA 0183 RX_B NMEA 0183 TX_A NMEA 0183 TX_B ECDIS TTYS1 2 Serial 1 1A blue blue white orange white orange RS422_RX RS422_RX RS422_TX RS422_TX ECDIS TTYS0 3 Serial 2 2B brown brown...

Страница 17: ...tion refer to Websocket interface connection on page 23 Talkers and Listeners Do not connect multiple Talkers to any serial input Rx of the unit The NMEA 0183 standard is not intended for this type o...

Страница 18: ...k to the E5024 system the following steps must be performed 1 Submit the User permit code to Navico 2 Verify your chart subscription from the NavTracker web site 3 Update the content of the NavStick t...

Страница 19: ...r the purchased charts are prepared These chart updates and Chart permit codes are downloaded to the NavStick by using the NavSync program Updating the content of the NavStick When the chart subscript...

Страница 20: ...y using the Install permits menu option When Chart permits are installed the charts have to be copied from an USB or SD drive to the E5024 system by using the Find and install charts menu option Selec...

Страница 21: ...e The following sections focus on settings that typically will not require change once configured User preference settings and operation are covered in the operator manual The ECDIS settings options a...

Страница 22: ...ety checks Note The Common Reference Point is a common point selected on the ship usually the con ning station to which all sensors are referenced to The Common Reference Point must be set in relation...

Страница 23: ...gs The image above shows a typical sensor page The upper section of the page is similar for all sensors The Mnemonic NMEA sentences eg GLL VTG shown are dependent on the Sensor type selected The follo...

Страница 24: ...transmitting device Use UDP Receiver to access ethernet sensors using the UDP protocol UDP Sender use to set the Host and Port settings Use UDP Sender to transmit data using the UDP protocol The Host...

Страница 25: ...he top right corner The data is shown in raw format and updated in real time Websocket interface connection The Simrad web interface is an easy to use web style portal that lets you configure NMEA 200...

Страница 26: ...ess into the web browser address bar Note Ensure that your computer s network settings are set so you can access this IP address 5 Once connected correctly the Simrad web interface home screen will ap...

Страница 27: ...main menu and the available sub menu tabs will be shown directly below as indicated Web interface help files Selecting the help tab located in the top righthand corner of the screen will show the help...

Страница 28: ...justment as is set by default for Simrad IMO radar Set the Data received timeout to stop overlay if no fresh data is provided Set an approximate location on vessel for the radar scanner Note Setting t...

Страница 29: ...Installation Manual System settings Display Used to change the color palette For more information refer to the E5024 Operator Manual Sound Used to turn the alarm sound On or Off On screen keyboard Use...

Страница 30: ...t be able to install it on the system Installing SA certificates To install an SA certificate 1 Go to Settings System and then select SA certificates A list of the currently installed SA certificates...

Страница 31: ...list when you have more than one ECDIS in the system Each ECDIS in the system must have a unique name PLECDIS To setup a PLECDIS system two or more E5000 devices need to be connected using a standard...

Страница 32: ...el to warn you in case dangerous or caution objects are found inside the guard zone Note A Navigational caution will appear on the screen if dangerous or caution objects are found within the guard zon...

Страница 33: ...e the zone tick off the Show on chart check box Note If the guard zone display is on dangerous objects inside the zone are marked with red and caution objects are marked with yellow If the guard zone...

Страница 34: ...e specified Any targets lost outside the specified range will not trigger an alarm You can turn off this alarm filter To turn On Off the lost radar target alarm Open the alarms panel by accessing the...

Страница 35: ...wer connection Description Refer Yes No Voltage Power connected to E5000 Power connected to Extenal alarm panel External equipment External equipment connected to Input Output from E5000 system Refer...

Страница 36: ...ber Description 000 0124 69 Micro C starter kit 120 ohm female terminator cap 120 ohm male terminator cap Micro C T piece connector Micro C 2 0 61M extension cable Micro C 15 4 55M extension cable Mir...

Страница 37: ...t Number Description 000 0127 51 Ethernet cable yellow 5 Pin 2 m 6 5 ft 000 0127 29 Ethernet cable yellow 5 Pin 4 5 m 15 ft 000 0127 30 Ethernet cable yellow 5 Pin 7 7 m 25 ft 000 0127 37 Ethernet cab...

Страница 38: ...ding Track Controller Autopilot Sentence B x DBT Depth Below Transducer x x 128267 DPT Depth x x 128267 DTM Datum Reference x All NMEA2000 Data is in WGS 84 Datum GGA Global Positioning System Fix Dat...

Страница 39: ...t Data x TTM Tracked Target Message x TXT supplementary to ALR with more info x VBW Dual Ground Water Speed x x 128259 VDM AIS VHF Data link Message x VDO AIS VHF Data Link Own Vessel Report x VHW Wat...

Страница 40: ...NSO evo2 Conformity CE C Tick HDMI Interfaces Ethernet 3 ports total 1 2 are PoE RJ45 socket NMEA 2000 compliant 1 port on rear Micro C male LEN 1 Video input 2 ports on rear BNC female NTCS or PAL fo...

Страница 41: ...m 9 14 281 mm 11 05 R 2 5 mm 0 1 R 4 2 m m 0 1 7 8 0 mm 0 31 66 mm 2 58 265 mm 10 42 130 mm 5 13 Note The dimensional drawings for the monitor and alarm panel are found in a separate document LTSX50N8...

Страница 42: ......

Страница 43: ...988 10788 001...

Отзывы: