Installation | 27
3
It will power a SimNet compatible instrument
system. Hence SimNet to other equipment can be
supplied via the autopilot, see Figure 2-20, Figure
2-21 and Figure 2-22.
4
SimNet must be properly terminated, i.e. unless it
is a small system (see Figure 2-20) there must be
terminations at each end of the Simrad backbone.
The SimNet network has to be terminated according to
the number and type of products connected.
In a small system consisting of maximum 5 SimNet
products and a total length of 5 m SimNet backbone
cable you only need the SimNet power cable with built in
termination (red disc on cable plug).
For additional information about SimNet ask for the
separate SimNet Manual.
AP24
IS20 Graphic
12V SimNet supply
T-joiner
T-joiner
5,5 m
5,5 m
5,5 m
Compass
Non SimNet
SimNet backbone
SimNet drop cable
24
AP
MODE
MENU
AUTO
STBY
TURN
10
10
PWR
1
1
RF25 Rudder Feedback
(SimNet cable with terminator)
AC12/AC42
Figure 2-20 SimNet network, small system