12 | Installation
Refer to the table below for recommended cable sizes.
Cable length
Drive unit voltage
1. Breaker panel to autopilot computer.
12 V
24 V
2. Autopilot computer to drive unit motor
(Length refers to each of the two cables)
AWG mm
2
AWG mm
2
Up to 3 m (10 ft.)
12
2,5
12
2,5
Up to 6 m (20 ft.)
10
4
10
2,5
Up to 10 m (32 ft.)
8
6
10
4
Up to 16 m (52 ft.)
6
10
8
6
Remove the bottom cover to get access to the plug-in
terminals.
Provide sufficient wire length so that the plug-in
terminals can be easily connected and disconnected.
Pull out each terminal before connecting the wires.
Remove all strands before putting back the terminal
cover.
Plug-in terminal
Cable strap
Cable retainer
Ground terminal
Fuse
Содержание AC12