![Simpson GCN-MEP Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/simpson/gcn-mep/gcn-mep_operators-manual_1278579008.webp)
T-SAS-GCNM12 ©
2012 Simpson Strong
-T
ie Company Inc.
-7-
PRINcIPLES ANd gUIdELINES fOR PROPER fASTENINg
FASTENING INTO CONCRETE AND MASONRY
Materials suitable for fastening into include:
– Poured concrete
– Precast concrete
– Pre-stressed concrete
– Grout-filled concrete block
– Grouted joints
Fasteners derive their holding power primarily from clamping of the concrete around
the fastener. Factors that influence a fastener driven into concrete include:
– Depth of penetration
– Compressive strength of concrete
– Fastener spacing and edge distance
– Fastener shank diameter
– Concrete aggregate
When operating the GCN150/GCN-MEP, always keep the tool perpendicular to the
work surface. Attempting to install fasteners other than at a 90˚ angle can result in pin
ricochet and cause:
– Injury to the user
– Injury to bystanders
– Damage to the tool
– Damage to the base material or attachment
FASTENER EDGE DISTANCE
Concrete: No less than 3" to nearest free edge.
MINIMUM DISTANCE BETWEEN FASTENINGS
No less than 3"
MINIMUM BASE MATERIAL THICKNESS
Concrete: No less than 3 times penetration depth of the fastener.