background image

T-SAS-GCNM12  ©

2012 Simpson Strong

-T

ie Company Inc.

-4-

SAfE HANdLINg Of gcN TOOLS ANd fUEL cELLS

  1. 

NEVER 

attempt to force a fuel cell into or out of the fuel compartment.

  2. 

NEVER 

use a sharp or pointed object to install or remove the fuel cell, this may 

cause an accidental discharge, or may puncture/damage the fuel cell, creating a 

hazardous condition.

  3. 

NEVER 

attempt to service a jammed tool with the battery and fuel cell installed.

  4.  If at any time during the operation of the tool you feel it is not working properly, 

STOP using it and call your Simpson Strong-Tie representative.

  5.  If unnecessary bystanders are in the area tell them to leave, 

 

warn all others that you are using a gas actuated tool.

  6.  Check the work surface to be sure it is clear of any debris. 

 

Clear away any debris so that the tool sits flush on the work surface.

  7.  Check the work area for explosive or flammable materials. 

 

If any are found remove them before operating the tool.

  8.  Remove any debris from the tool barrel before operating.
  9.  Check the air filter for cleanliness and condition; if necessary, replace with new 

filter (part # GCN-BC0597) or clean prior to operating tool.

 10. 

NEVER

 load more than one fastener in the barrel or fastener guide for any reason.

 11. Should a tool become disabled for any reason, immediately remove the fuel cell 

and battery, and tag the tool “Defective Tool.” Do not resume operation until the 

disabled tool has been repaired according to manufacturer’s instructions.

For cleaning procedures, please refer to 

www.strongtie.com/GCNcleaning

Содержание GCN-MEP

Страница 1: ...OPERATOR S MANUAL GCN150 GCN MEP GAS ACTUATED CONCRETE NAILER 5956 W Las Positas Blvd Pleasanton CA 94588 www strongtie com Read This Manual Before Operating This Tool WARNING...

Страница 2: ...for information Reading and understanding this manual is YOUR RESPONSIBILITY B LIMITATIONS 1 Just as no instruction book of any kind can forewarn against all possible situations or emergencies that ma...

Страница 3: ...g the Fuel Cell 14 Installing the Battery 15 Charge Indicator Light 15 Installing the Tool Boot for the Extension Pole 16 Installing the Tool Foot GCN MEP only 16 Depth Control Dial 15 Troubleshooting...

Страница 4: ...fe functioning of the tool Use only genuine Simpson Strong Tie parts fasteners and fuel cells at all times 6 Operators and bystanders must wear eye and ear protection and head protection is recommende...

Страница 5: ...ou are using a gas actuated tool 6 Check the work surface to be sure it is clear of any debris Clear away any debris so that the tool sits flush on the work surface 7 Check the work area for explosive...

Страница 6: ...could pass completely through the base material causing serious injury or death 3 If the fastener sinks into the material with the hammer blow the material is too soft and is unsuitable If the materi...

Страница 7: ...ld cause the fastener to pass through and escape resulting in serious injury or death 8 Never fasten through an existing hole in any material as the fastener could hit the edge of the hole and ricoche...

Страница 8: ...ude Depth of penetration Compressive strength of concrete Fastener spacing and edge distance Fastener shank diameter Concrete aggregate When operating the GCN150 GCN MEP always keep the tool perpendic...

Страница 9: ...holding force of the fastener is a function of the gripping action of the steel base material around the fastener and the fusion of the fastener to the base material Factors that influence the holding...

Страница 10: ...150 GCN MEP Mechanical Electrical and Plumbing Pins All single shot pins are 125 diameter and 1 in length unless specified Model No Description Pack Qty Compatible Gas Actuated Nailer GRH25 R100 1 4 R...

Страница 11: ...e 3 Release the pin feeder boot behind the last pin The feeder boot will automatically retract and engage the pins general operating instructions for the gcn150 gas actuated tool The magazine is desig...

Страница 12: ...hen loading a fastener into the fastener guide make sure no fingers are on the trigger and the trigger is not depressed Insert the fastener without forcing the fastener guide to depress and retract in...

Страница 13: ...ns have a smaller head diameter than the single shot preassembled pins which requires changing the fastener guide The fastener guide can easily be changed without tools in seconds 1 Remove the yellow...

Страница 14: ...to the back of the magazine 3 Release the pin feeder boot and slide it back until it is against the last pin The magazine is designed to retain two pins during use to prevent the tool from discharging...

Страница 15: ...actuated tool 1 Remove safety cap from metering valve 2 Insert front legs of metering valve inside top shoulder of fuel cell 3 Push the back legs inside top shoulder of fuel cell until it snaps into...

Страница 16: ...e Simpson Strong Tie recommends charging the battery for at least 15 minutes every three months for optimal battery life The GCN MEP tool has a battery charge indicator light 1 When the light is sold...

Страница 17: ...the engine cover making sure the trigger hook is around the trigger 3 While depressing the fastener guide against a firm surface install the long engine cover bolts supplied with the boot kit model nu...

Страница 18: ...battery Empty fuel cell Replace with new GFC34 fuel cell Reduction or loss of power Piston is not returned to ready position Clean tool and remove excess carbon built up in barrel Damaged seal Replac...

Страница 19: ...ption Length PETG 6KT Complete tool with boot handle and one extension 6 ft PETG 8KT Complete tool with boot handle and two extensions 8 ft PETH2 Handle 2 ft PETG Boot N A PETS2 Pole extension 2 ft PE...

Страница 20: ...IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU S...