11
SimpliFire • SF-ALL48-BK, SF-ALL60-BK • 2040-981 Rev. C • 3/18
Figure 4.4 Adjust Bracket Location
Figure 4.6 Securing the Appliance
C. Recessed in 2 x 4 Framed Wall
1. Prepare wall opening:
SF-ALL48-BK
:
• 44-5/16 in. x 18-1/8 in. opening in framing
SF-ALL60-BK:
• 56-1/8 in. x 18-1/8 in. opening in framing
• The width of the framing on the left and right sides
of the opening must be 3 in.. This is needed for the
wallboard finishing and to secure the appliance into
the opening. See Figure 4.1.
•
Allow 1-1/2 in. of wood exposed after finishing the
wallboard. See Figure 4.1.
2. Install the appliance into the opening (See Figure
4.7). Level the appliance. Ensure that it is centered
left to right, then fasten it directly to the framing with
two (2) ST4X25 wood screws in both the left and
right sides of the skirt. See Figure 4.7.
3. Connect to electrical service. Reference Section 4.E.
Locate and attach the Fixing
Brackets so that dimension
is 1/16 - 1/8 in. greater than
the thickness of the wall
-
board.
Figure 4.5 Adjust Bracket Location
Verify gap of 1/16 to 1/8 in. after
installing four(4) ST4X25 Wood
Screws.
Appliance should be supported by this framing.
WOOD
SCREWS
WOOD
SCREWS
WOOD
SCREWS
Figure 4.7 Securing the Appliance with Skirt