background image

9

 of 12

Description of Functions and Operation

How the room temperatur controller can be used.

Change temperature until next switching event

> see 

keys + – in AUTO

Controlling the temperature according to pre-set profiles

> see 

main menu, AUTO

Set a constant temperature (manual operation) 

> see 

main menu, MAN

Set temperature for a number of hours                          

> see 

main menu, TIMER

Set temperature for a specific date                           

> see 

main menu, HOLIDAY

Use a separate program for special days 

> see 

main menu, AT HOME

Adjust the controller to personal needs

> see 

main menu, USER SETTINGS

Adjust the controller to application needs                   

> see

 main menu, INSTALLER SETTINGS

    

   Keys

to confirm / activate

+ – in AUTO (-)

Set temperature temporarily until next switching event. Indicated by „-“ 

behind 

AUTO-. 

First key-press shows set value, following ones change it.

OK

+ – in menu

Scroll through the menu

OK

Accepts modification / selection

Info

Show related details in 

AUTO, MAN, TIMER, HOLIDAY, AT-HOME

To cancel press key again.

Menu

Enter menus. + – key to move

Go one step back

 for 10 sec.

Switch off connected load. Display shows 

OFF

. Details see G4

Main Menu

to confirm / activate

A MENU

Use 

+ –

 

keys 

in order to navigate through the menu

B AUTO

The temperature will be controlled automatically according to the time 

and temperature of the selected program, see G1. Use 

+ – keys

 to 

change temperature until next switching event.

OK

C MAN

The temperature will be controlled continuously according to the tem-

perature set in this menu. Use 

+ – key

 to change temperature.

OK

D TIMER

The temperature will be controlled temporarily according to the hours 

and temperature set in this menu. On terminating 

TIMER

 mode, the pre-

viously active mode will be re-activated. 

HOLIDAY

 terminates 

TIMER

.

OK

E HOLIDAY

The temperature will be controlled between the dates and the tempe-

rature set in this menu. 

HOLIDAY

 starts at 0 h of the first day, it ends at 

24 h of the last day. In the period of time before 

HOLIDAY 

starts, 

AUTO

 

will be active. While waiting for holiday start date, other mode can be 

selected 

(AUTO, MAN, TIMER, HOME)

.

 INFO

 provides details of the 

pending holiday. In this situation holiday period will start automatically 

when the DATE FROM occurs. When holiday ends it returns to the mode 

which was in place before activating 

HOLIDAY

.

OK

F AT HOME

The temperature will be controlled automatically according to the time 

and temperature of the program configured here (independent from 

AUTO

). The program is the same for all days. Monday‘s program is used 

as the pre-set. It needs to be terminated by user, e.g, by selecting 

AUTO

Usage: for holiday at home, illness etc.

OK

G USER SETTINGS

Customise the controller according to personal requirements

OK

H INSTALLATER

SETTINGS

Customise the controller according to application requirements 

(from installer only)

OK

Содержание RTL-TH DIGITAL

Страница 1: ...per day and temperatures according to personal needs After installation the device automatically shows the time of day and the room temperature In AUTO mode the heater will be automatically acti vated according to programmed time and tempera ture Program 1 is the default pre set program see 8 room temperature controller Room temperature will be regulated based on the Work on heating systems must o...

Страница 2: ... or bathtubs 1 The regulation box has to be arranged outside of the zones 0 1 and 2 in conformity with DIN VDE 0100 701 to prevent contact with splashing water Prepare the insulation box for the mounting by inserting the fixing clips from the backside into the drill holes at the corner points of the box and securing them with the supplied screws so that they cannot fall out 2 The fixing clips are ...

Страница 3: ...d in compli ance with all applicable safety regulations To maintain compliance with Protection Class II user access to the rear of the device must be pre vented This electronic device is an independently moun ted regulation It is used to control the temperature only in dry and cloesed rooms under normal envi ronmental conditions It conforms to EN 60730 and works according to operating principle 1C...

Страница 4: ...g screw 6c Eletcric Connection Remove the splash guard for connecting terminal in the box 7a Caution Disconnect electric circuit from supply Connecting according to wiring diagram For solid and flexible wires 1 2 5 mm2 The return temperature sensor plug 3 and 4 on the regulation box can be connected by using a 2 lead cable suitable for 230 V up to 50 m Avoid laying sensor cable alongside power cab...

Страница 5: ...Cable layout 0 5 mm 2 lead Actuator Connection thread M 30 x 1 5 Rated voltage 230 V Maximum switch on 0 5 A Continuous output 2 5 3 W Design normally closed Degree of protection Protection class IP42 II Overtension protection Position indication present 6 Ventilation The system can be ventilated as necessary using the ventilation valve installed 7 Flowmeter Flowmeter regulating valve for the regu...

Страница 6: ... 10 sec Holiday Mode date from until can be set Timer Party specific temperature for configurable duration Energy consumption display heating on time cost for last 2 days week month year Energy cost per hour configurable Frost protection Range limits for adjusting max and min temp Access protection Operating language can be selected Valve protection Adaptation to valves normally open or normally c...

Страница 7: ...the new desired temperature The program will then continue to run as normal Selecting pre set setting times programs Press key 1 to return to the menu Press key 3 six times until the menu option USER SETTINGS appears Press key 4 OK to select this sub menu This will bring up menu option 6 1 SELECTPROGRAM Press key 4 to select the menu Select the desired program 1 to 3 with keys 2 or 3 and confirm w...

Страница 8: ... to Friday Events 1 2 3 4 5 6 Time 06 00 08 30 12 00 14 00 17 00 22 00 Temperature C 21 0 18 0 21 0 18 0 21 0 15 0 Saturday and Sunday Events 1 2 Time 07 00 23 00 22 00 Temperature C 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00 h 16 00 h 18 00 h 20 00 h 22 00 h Mo Fr Sa So 23 00 22 00 23 00 for Saturday Program 3 Monday to Friday Events 1 2 3 4 Time 06 00 08 30 17 00 22 00 Temperature C 21 0 18 0...

Страница 9: ...ee G1 Use keys to change temperature until next switching event OK C MAN The temperature will be controlled continuously according to the tem perature set in this menu Use key to change temperature OK D TIMER The temperature will be controlled temporarily according to the hours and temperature set in this menu On terminating TIMER mode the pre viously active mode will be re activated HOLIDAY termi...

Страница 10: ... Key Lock Protect controller against unauthorised use Re activate via code 93 NO 7 Room temperature limits min max Limits the temperature which can be set by the user If both values are the same no adjustment is possible This affects AUTO MAN HOL TIMER AT HOME EVENT SETTING G2 The active program mode will not be affected automatically 5 30 C 8 Cost Hr for Energy The assumed energy cost per hour in...

Страница 11: ...0 00 h in the morning 3 min OFF 1 10 6 Frost protection Set frost protection temperature Only if controller is switched OFF the temperature will be controlled to that value see G4 5 C OFF 5 30 7 Optimum start The set temperature will be reached at the time specified in the pro gram During pre heating time AUTO_ will be displayed YES 8 Valves NO If valves normally open have to be used NO 9 Energy c...

Страница 12: ...located on the printed circuit board inside this product can be removed at the end of the product life by professional personnel only A B C D E F G H I K G 3 4 a 50 211 197 27 156 138 64 210 270 Data in mm 02 2019 The illustrations are symbolic and may differ from the res pective product Errors and technical changes reserved wall box wall box Simplex Armaturen Systeme GmbH Isnyer Straße 28 Tel 49 ...

Отзывы: