7
of 12
Setting a
constant room
temperature
without the timer
programming -
function
“manual“
Press
key 1
to access the menu. Press
key 3
(+) twice until the menu option
MAN
appears.
Select this mode by pressing
key 4
(OK). Selecting this option will automatically take you from
the menu and return you to the normal display mode.
MAN
will be displayed at bottom left of
the display.
The desired room temperature can be set using
keys 2
(-) and
3
(+).
This will apply until altered; timer programs are deactivated.
Activating timer
programming -
function
“automatic“
Press
key 1
to return to the menu. Press
key 3
(+) once until the menu option
AUTO
appears.
Select thus mode by pressing
key 4
(OK).
Selecting this option will automatically take you
from the menu and return you to the normal display mode.
AUTO
will be displayed at bottom
left of the display.
If no other selection has been made, pre-set timer program 1 will be active.
Changing the
currently
selected room
temperature
Set the desired room temperature from the normal display by pressing
keys 2
(-) or
3
(+) and
confirm with
key 4
(OK).
During the change the desired temperature will flash, then the display will change back to the
standard setting (either desired or current temperature, as required – see Complete Instructions
G10).
If the
MAN
function is active, the change will be permanently set as the new desired
temperature. If the
AUTO
feature is active, the change will be valid until the next programmed
timer switch time. When this time is reached, the programmed temperature will be set
as the new desired temperature. The program will then continue to run as normal.
Selecting pre-set
setting times
(programs)
Press
key 1
to return to the menu. Press
key 3
(+) six times until the menu option
USER
SETTINGS
appears.
Press
key 4
(OK) to select this sub-menu. This will bring up menu option
6.1 SELECT PROGRAM
.
Press
key 4
to select the menu. Select the desired program (1 to 3) with
keys 2
(-) or
3
(+) and
confirm with
key 4
(OK).
Leave the menu by pressing
key 1
(
) twice.
Programming
your own setting
times
See room thermostat complete Instructions 8.4
8.3 Short Instructions Installer Settings
Setting the
return tempera-
ture in the floor
circuit
Press
key 1
to access the menu. Press
key 3
(+) seven times until the menu option
INSTALLER SETTINGS
appears.
Press
key 4
(OK) to select this sub-menu.
The menu option H1
APPLICATION
will appear. Press
key 3
two more times to reach
menu option H3
RETURN TEMP LIMITS MIN/MAX.
Press
key 4
(OK) to select this menu.
You will first see the lower temperature limit flashing. The standard setting here is
OFF
. If
desired, you can press
keys 2
(-) and
3
(+) to set the lower temperature limit, i.e. the lowest
return water temperature, within the range 10°C to 35°C. The recommended setting is
OFF
.
Confirm the value displayed by pressing
key 4
(OK). You will automatically go back to the
display used for setting the upper return temperature limit. This can be altered within the
range 10 °C to 50 °C.
Note
: due to the latency of the valve actuator, a higher water temperature may briefly be
achieved! To avoid unnecessary temperature spikes in the floor temperature, select the
minimum temperature for optimal living comfort. The standard setting is 35 °C.
Confirm again using
key 4
(OK) and leave the menu by pressing
key 1
(
) twice.