background image

7

 of 12

Setting a 

constant room 

temperature 

without the timer 

programming -  

function  

“manual“

Press 

key 1

 to access the menu. Press 

key 3

 (+) twice until the menu option 

MAN

 appears. 

Select this mode by pressing 

key 4

 (OK). Selecting this option will automatically take you from 

the menu and return you to the normal display mode. 

MAN

 will be displayed at bottom left of 

the display. 

The desired room temperature can be set using 

keys 2

 (-) and 

3

 (+).  

This will apply until altered; timer programs are deactivated.

Activating timer  

programming -   

function  

“automatic“

Press 

key 1

 to return to the menu. Press 

key 3

 (+) once until the menu option 

AUTO

 appears. 

Select thus mode by pressing 

key 4

 (OK). 

Selecting this option will automatically take you  

from the menu and return you to the normal display mode. 

AUTO

 will be displayed at bottom 

left of the display. 

If no other selection has been made, pre-set timer program 1 will be active.

Changing the  

currently 

selected room 

temperature

Set the desired room temperature from the normal display by pressing 

keys 2

 (-) or 

3

 (+) and 

confirm with 

key 4

 (OK). 

During the change the desired temperature will flash, then the display will change back to the 

standard setting (either desired or current temperature, as required – see Complete Instructions 

G10).  

If the 

MAN

 function is active, the change will be permanently set as the new desired  

temperature. If the 

AUTO

 feature is active, the change will be valid until the next programmed 

timer switch time. When this time is reached, the programmed temperature will be set  

as the new desired temperature. The program will then continue to run as normal.

Selecting pre-set 

setting times  

(programs)

Press 

key 1

 to return to the menu. Press 

key 3

 (+) six times until the menu option 

USER

  

SETTINGS

 appears. 

Press 

key 4

 (OK) to select this sub-menu. This will bring up menu option 

6.1 SELECT PROGRAM

.  

Press 

key 4 

to select the menu. Select the desired program (1 to 3) with 

keys 2

 (-) or 

3

 (+) and 

confirm with 

key 4

 (OK). 

Leave the menu by pressing 

key 1

 (

) twice.

Programming 

your own setting 

times

See room thermostat complete Instructions 8.4

8.3 Short Instructions Installer Settings

Setting the 

return tempera-

ture in the floor 

circuit

Press 

key 1

 to access the menu. Press 

key 3

 (+) seven times until the menu option  

INSTALLER SETTINGS

 appears. 

Press 

key 4

 (OK) to select this sub-menu. 

The menu option H1 

APPLICATION

 will appear. Press 

key 3

 two more times to reach 

menu option H3 

RETURN TEMP LIMITS MIN/MAX.

 Press 

key 4

 (OK) to select this menu. 

You will first see the lower temperature limit flashing. The standard setting here is 

OFF

. If 

desired, you can press 

keys 2

 (-) and 

(+) to set the lower temperature limit, i.e. the lowest 

return water temperature, within the range 10°C to 35°C. The recommended setting is 

OFF

.  

Confirm the value displayed by pressing 

key 4

 (OK). You will automatically go back to the 

display used for setting the upper return temperature limit. This can be altered within the  

range  10 °C to 50 °C.

Note

: due to the latency of the valve actuator, a higher water temperature may briefly be  

achieved! To avoid unnecessary temperature spikes in the floor temperature, select the  

minimum temperature for optimal living comfort. The standard setting is 35 °C.  

Confirm again using 

key 4 

(OK) and leave the menu by pressing 

key 1

 (

) twice.

Содержание RTL-TH DIGITAL

Страница 1: ...per day and temperatures according to personal needs After installation the device automatically shows the time of day and the room temperature In AUTO mode the heater will be automatically acti vated according to programmed time and tempera ture Program 1 is the default pre set program see 8 room temperature controller Room temperature will be regulated based on the Work on heating systems must o...

Страница 2: ... or bathtubs 1 The regulation box has to be arranged outside of the zones 0 1 and 2 in conformity with DIN VDE 0100 701 to prevent contact with splashing water Prepare the insulation box for the mounting by inserting the fixing clips from the backside into the drill holes at the corner points of the box and securing them with the supplied screws so that they cannot fall out 2 The fixing clips are ...

Страница 3: ...d in compli ance with all applicable safety regulations To maintain compliance with Protection Class II user access to the rear of the device must be pre vented This electronic device is an independently moun ted regulation It is used to control the temperature only in dry and cloesed rooms under normal envi ronmental conditions It conforms to EN 60730 and works according to operating principle 1C...

Страница 4: ...g screw 6c Eletcric Connection Remove the splash guard for connecting terminal in the box 7a Caution Disconnect electric circuit from supply Connecting according to wiring diagram For solid and flexible wires 1 2 5 mm2 The return temperature sensor plug 3 and 4 on the regulation box can be connected by using a 2 lead cable suitable for 230 V up to 50 m Avoid laying sensor cable alongside power cab...

Страница 5: ...Cable layout 0 5 mm 2 lead Actuator Connection thread M 30 x 1 5 Rated voltage 230 V Maximum switch on 0 5 A Continuous output 2 5 3 W Design normally closed Degree of protection Protection class IP42 II Overtension protection Position indication present 6 Ventilation The system can be ventilated as necessary using the ventilation valve installed 7 Flowmeter Flowmeter regulating valve for the regu...

Страница 6: ... 10 sec Holiday Mode date from until can be set Timer Party specific temperature for configurable duration Energy consumption display heating on time cost for last 2 days week month year Energy cost per hour configurable Frost protection Range limits for adjusting max and min temp Access protection Operating language can be selected Valve protection Adaptation to valves normally open or normally c...

Страница 7: ...the new desired temperature The program will then continue to run as normal Selecting pre set setting times programs Press key 1 to return to the menu Press key 3 six times until the menu option USER SETTINGS appears Press key 4 OK to select this sub menu This will bring up menu option 6 1 SELECTPROGRAM Press key 4 to select the menu Select the desired program 1 to 3 with keys 2 or 3 and confirm w...

Страница 8: ... to Friday Events 1 2 3 4 5 6 Time 06 00 08 30 12 00 14 00 17 00 22 00 Temperature C 21 0 18 0 21 0 18 0 21 0 15 0 Saturday and Sunday Events 1 2 Time 07 00 23 00 22 00 Temperature C 21 0 15 0 6 00 h 8 00 h 10 00 h 12 00 h 14 00 h 16 00 h 18 00 h 20 00 h 22 00 h Mo Fr Sa So 23 00 22 00 23 00 for Saturday Program 3 Monday to Friday Events 1 2 3 4 Time 06 00 08 30 17 00 22 00 Temperature C 21 0 18 0...

Страница 9: ...ee G1 Use keys to change temperature until next switching event OK C MAN The temperature will be controlled continuously according to the tem perature set in this menu Use key to change temperature OK D TIMER The temperature will be controlled temporarily according to the hours and temperature set in this menu On terminating TIMER mode the pre viously active mode will be re activated HOLIDAY termi...

Страница 10: ... Key Lock Protect controller against unauthorised use Re activate via code 93 NO 7 Room temperature limits min max Limits the temperature which can be set by the user If both values are the same no adjustment is possible This affects AUTO MAN HOL TIMER AT HOME EVENT SETTING G2 The active program mode will not be affected automatically 5 30 C 8 Cost Hr for Energy The assumed energy cost per hour in...

Страница 11: ...0 00 h in the morning 3 min OFF 1 10 6 Frost protection Set frost protection temperature Only if controller is switched OFF the temperature will be controlled to that value see G4 5 C OFF 5 30 7 Optimum start The set temperature will be reached at the time specified in the pro gram During pre heating time AUTO_ will be displayed YES 8 Valves NO If valves normally open have to be used NO 9 Energy c...

Страница 12: ...located on the printed circuit board inside this product can be removed at the end of the product life by professional personnel only A B C D E F G H I K G 3 4 a 50 211 197 27 156 138 64 210 270 Data in mm 02 2019 The illustrations are symbolic and may differ from the res pective product Errors and technical changes reserved wall box wall box Simplex Armaturen Systeme GmbH Isnyer Straße 28 Tel 49 ...