S4010-0011-5  11/2015

Model 

Features 

Supervisory 

Current 

Alarm 

Current 

Mounting Requirements 

4010-9909 

City Connect Module w/ disconnect switches 

20 mA 

36 mA 

Select one maximum, mounts 
on ESS 

4010-9910 

City Connect Module 

20 mA 

36 mA 

4010-9911 

Alarm Relay Module 

15 mA 

37 mA 

4190-6105* 

TrueInsight Remote Gateway 

62 mA 

62 mA 

Mounts on Front Door 

4100-5128 

Battery Distribution Terminal Block, mounts to side of box, required when battery connection leaves the 4010ES 
box (also used in the 4100ES fire alarm control panel) 

* Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details. 

 

LED Kits 

(LEDs are pluggable, use to change color for local application requirements)

 

Model 

Description 

4100-9843 

8 Yellow LED Kit 

4100-9844 

8 Green LED Kit 

4100-9845 

8 Red LED Kit 

4100-9855 

8 Blue LED Kit 

End User Programming Tools 

Model 

Description 

4100-8802 

End User Programming Unit Software 

4100-0292 

Custom Label Editing (USB Dongle) 

4100-0295 Port 

Vectoring 

Setup and Control (USB Dongle) 

4100-0296 

Access Level/Passcode Editing (USB Dongle) 

4100-0298 

WalkTest Configuration Setup and Control (USB Dongle) 

Factory Programming Options 

Model 

Description 

4010-8810 

Factory Programming (select) 

4010-0831 

Custom Labels and Programming (requires 4010-8810) 

 Cabinet Dimension Reference 

 Miscellaneous Accessories 

 Additional Panel Option Selection (block space is not used)  

Содержание 4010-9601

Страница 1: ...either Class B or Class A operation 48 LED panel mount annunciation provides 40 Red and 8 Yellow pluggable LEDs select models meets ULC requirements optional LED kits are available to change individual LED color to Green or Blue to meet specific site requirements Optional ESS mounted modules door mounted modules and other options include City Connect with or without disconnect switches Alarm Relay...

Страница 2: ...of the 4010ES ESS There are 3 available 4 x 5 blocks for mounting 4010ES hardware options Other 4010ES Options The 4010ES City Connect module or the optional Alarm Relay module mount directly to the ESS These options are mutually exclusive Network Media modules mount directly to the 4010ES Network Interface Card The TrueInsight Remote Gateway mounts on the back side of the 4010ES User Interface Pa...

Страница 3: ... point category and point selection alphabet characters are not used at this time ADDITIONAL FUNCTION KEYS Event Time Request More Information Request Lamp Test Elevator Bypass City Disconnect Ground Fault Waterflow West Waterflow East Custom label insert LCD NAVIGATION CONTROL Menu selection Vertical and Horizontal position selection buttons 2 X 40 LCD READOUT LCD is backlighted during normal con...

Страница 4: ...details TrueAlarm heat sensors can be selected for fixed temperature detection with or without rate of rise detection Utility temperature sensing is also available typically to provide freeze warnings or alert to HVAC system problems Readings can selected as either Fahrenheit or Celsius TrueSense Early Fire Detection Multi sensor 4098 9754 provides photoelectric and heat sensor data using a single...

Страница 5: ...by appliances on the notification appliance circuit NAC making it much more difficult and costly to locate and correct the source of a problem Using the TrueAlert magnet test allows each appliance to individually identify its candela setting and address and to briefly operate if desired and using the TrueAlert ES Appliance Self Test feature provides detailed performance verification per appliance ...

Страница 6: ...epending on model see model selection below for additional details on specific models Cabinet and door 6 A Enhanced System Supply details Two 3 A Class B IDNAC SLCs for up to 254 addressable notification appliances Class A operation is available using the 4010 9930 Dual Class A IDNAC Isolator DCAI module Up to 2 A of auxiliary power 110 Ah UL 50 Ah ULC battery charger 33 Ah maximum in the control ...

Страница 7: ...from the list below 2 Vertical Blocks NA NA 4010 9922 Modular Network Interface Card requires two media modules see below 2 Vertical Blocks 30 mA 30 mA 4010 9818 Network Media Card Wired N A mounts to 4010 9922 55 mA 55 mA 4010 9819 Network Media Card Fiber Optic 25 mA 25 mA 4010 9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA 4010 9923 SafeLINC Internet Interface 2 Vertical B...

Страница 8: ...representative for more details LED Kits LEDs are pluggable use to change color for local application requirements Model Description 4100 9843 8 Yellow LED Kit 4100 9844 8 Green LED Kit 4100 9845 8 Red LED Kit 4100 9855 8 Blue LED Kit End User Programming Tools Model Description 4100 8802 End User Programming Unit Software 4100 0292 Custom Label Editing USB Dongle 4100 0295 Port Vectoring Setup an...

Страница 9: ...iator English 1 4606 9102CF 4010ES RUI LCD Annunciator French 1 for Canada 4602 9101 Status Command Unit SCU LED Annunciator 1 4602 9102 Remote Command Unit RCU LED Annunciator w control 1 4602 9150 Graphic I O RCU SCU Assembly for custom annunciator panels 1 4602 7101 Graphic I O RCU SCU Assembly for custom annunciator panels 1 4602 7001 RCU for cabinet mount 1 4602 6001 SCU for cabinet mount 1 4...

Страница 10: ...ence Installation Instructions 579 1150 Operating Instructions 579 969 Subject Data Sheet Subject Data Sheet 4010ES Agent Release Applications and Accessories S4010 0005 Network Communications S4100 0056 Agent Release Accessories S2080 0010 Multi Signal Fiber Optics S4100 0049 Building Network Interface S4100 0061 4602 Series SCU RCU S4602 0001 SafeLINC Internet Interface S4100 0062 PC Annunciator...

Отзывы: