Introduction 

 

4007ES Series Fire Detection and Control Panels

 

provide extensive installation, operator, and service features 

with point and module capacities suitable for a wide range of 

system applications. The convenient and intuitive color 

touchscreen provides easy access for typical system response 

actions and for detailed system review or configuration 

updates with password control to limit user access. 
IDNet+ addressable initiation communications and IDNAC 

addressable notification communications are standard 

features. (Refer to data sheet S4007-0001 for 4007ES panels 

providing conventional notification.) 

Operator Interface 

 

Convenient Status Information.

 With the locking door 

closed, the glass window allows viewing of the display 

status LEDs. The user interface is a 4.3” diagonal color 

touchscreen LCD with separate status LEDs as shown 

below. 
LED indicators describe the general category of activity 

being displayed with the LCD providing more detail. For the 

authorized user, unlocking the door provides access to the 

control functions and allows further inquiry by scrolling the 

display for additional detail. 

 

Operator Interface and Software Features  

 

 

Convenient and detailed operator information is easily 

accessed using a logical, menu-driven touchscreen 

display with password access control 

 

Multiple automatic and manual diagnostics for 

maintenance reduction 

 

Operator Interface Features 

(Continued)

 

 

 

Alarm and Trouble History Logs (up to 1000 entries for 

each, 2000 total events) are available for viewing from 

the display or to be downloaded to a service computer or 

to the USB drive 

 

Module level ground fault searching assists installation 

and service by locating and isolating modules with 

grounded wiring 

 

WALKTEST silent or audible system test performs an 

automatic self-resetting test cycle and supports up to 8 

WALKTEST groups 

 

Install Mode

 allows grouping of multiple troubles for 

uninstalled modules and devices into a single trouble 

condition (typical with future phased expansion); with 

future equipment and devices grouped into a single 

trouble, operators can more clearly identify events 

from the commissioned and occupied areas 

Mechanical Description 

 

 

Locking door with polycarbonate window

 

 

 

Latching front panel assembly swings forward for 

convenient internal access 

 

Smooth box surfaces are provided for locally cutting 

conduit entrance holes exactly where required 

 

Modules are power-limited (except as noted, such as 

relay modules) 

 

Battery compartment (bottom) accepts two batteries, 

up to 18 Ah, to be mounted within the cabinet without 

interfering with module space; charger capacity is up 

to 33 Ah; for batteries greater than 18 Ah, refer to 

page 7 for external battery cabinet details 

 

Cabinet assembly design has been seismic tested and 

is certified to IBC and CBC standards as well as to 

ASCE 7 categories A through F, requires battery 

brackets as detailed on data sheet S2081-0019 

 

 

S4007-0002-6  11/2015

Alarm Indicator

 red LED

Priority 2 Indicator

 

red LED

Supervisory 

Indicator

 yellow LED

Trouble Indicator

 

yellow LED

Alarm Silenced

yellow LED

AC Power 

green LED

3 Programmable LEDs with Custom 

Label Insert; 

top two selectable as 

Red or Yellow, bottom selectable as 

Green or Yellow

Color Touchscreen LCD 

with 

sample Fire Alarm List showing

 

 

 Touchscreen Display with LED Status Indicators 

(approximately full size)

 

Содержание 4007-9201

Страница 1: ...on board memory to allow easy selection of desired revision An internal Ethernet service port and an internal serial service port are available for service computer connections to perform configuratio...

Страница 2: ...puter or to the USB drive Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring WALKTEST silent or audible system test performs an...

Страница 3: ...in Menu May 27 2015 12 24 PM System Trouble Screen identifies active troubles with custom labels displayed arrows allow navigation through the list Trouble Log Screen allows review of past troubles wi...

Страница 4: ...data sheet S4098 0052 for details TrueAlarm heat sensors can be selected for fixed temperature detection with or without rate of rise detection Utility temperature sensing is also available typically...

Страница 5: ...area zone covered by appliances on the notification appliance circuit NAC making it much more difficult and costly to locate and correct the source of a problem Using the TrueAlert magnet test allows...

Страница 6: ...num Models with BA are available assembled in the USA by adding the suffix BA 6 S4007 0002 6 11 2015 Factory Programming Options Model Description 4007 8810 Factory Programming select 4007 0831 Custom...

Страница 7: ...tion Manual 579 1103 4007ES Hybrid Data Sheet S4007 0001 Detailed Operator s Manual 579 1165 Field Installed Optional Modules Model Description Supv Alarm 4190 8001 TrueInsight Remote Service Gateway...

Страница 8: ...9803 IDNet Loop Expansion Modules maximum of two two are shown 4 IDNAC Power Supply Assembly 5 Location for additional 4007 9801 Zone Relay Module 6 Location for additional 4007 9801 Zone Relay Module...

Страница 9: ...009 IDNet NAC Extender S4009 0002 Battery and Battery Cabinet Reference S2081 0006 4003EC Voice Control Panel S4003 0002 Seismic Battery Brackets Reference S2081 0019 4606 Series Color LCD Touchscreen...

Страница 10: ...f Test TrueAlert addressable appliance not TrueAlert ES addressable appliance Note Additional TrueAlert ES Self Test information is detailed in Operating Instructions 579 1165 shipped with the panel S...

Отзывы: