Service Port 

 

Page 1

REPORT 10  TrueAlertES Self-Test Report 

12:34:56pm   MON  01-JUN-15

Point ID 

Custom Label 

Date 

Visual 

Audible 

T1-1-1 

VO FIRST FLOOR (up to 40 characters)

01-JUN-15

NO OUT 

N/A

T1-2-5 

AV FIRST FLOOR EAST WING 

01-JUN-15

NO OUT 

NORMAL

T7-3-55 

AO SECOND FLOOR EAST WING

01-JUN-15

N/A 

NO OUT

T8-2-45 

AV SECOND FLOOR ROOM 29 

01-JUN-15

NOT TST 

N/A

T8-2-60 

AV SECOND FLOOR ROOM 22 

01-JUN-15

NORMAL 

NORMAL

T1-2-4 

AO FIRST FLOOR ROOM 17 

01-JUN-15

N/A 

UNSUPP

TRUEALERT_ES SELF-TEST REPORT COMPLETED 

 

 

 

 

Press RETURN for next Screen OR CTRL-X to abort 

 

 

Results Description: 
NORMAL

 = works correctly 

NO OUT

 = No Output, no light or sound was detected 

NOT TST

 = no result; either the appliance did not return a result before the test ended or the test was conducted as silent (strobes 

only) and audible appliance was not activated 

N/A

 = not applicable (no strobe on audible only, etc.) 

UNSUPP

 = appliance not compatible with Self-Test (TrueAlert addressable appliance not TrueAlert ES addressable appliance) 

Note:

 Additional TrueAlert ES Self-Test information is detailed in Operating Instructions 579-1165 shipped with the panel. 

Service Port 

 

Page 1

REPORT 10  TrueAlertES Self-Test Report 

12:34:56pm   MON  01-JUN-15

Point ID 

Custom Label 

Date 

Visual 

Audible 

T1-1-1 

VO FIRST FLOOR 

01-JUN-15

NO OUT 

N/A

T1-2-5 

AV FIRST FLOOR EAST WING 

01-JUN-15

NO OUT 

NORMAL

T1-2-6 

AV FIRST FLOOR NORTH ENTRANCE

12-MAY-15

NO OUT 

NORMAL

T7-3-55 

AO SECOND FLOOR EAST WING

01-JUN-15

N/A 

NO OUT

T8-2-45 

AV SECOND FLOOR ROOM 29 

01-JUN-15

NOT TST 

N/A

T1-1-11 

AV FIRST FLOOR SOUTH ENTRANCE

12-MAY-15

NORMAL 

NORMAL

T8-2-60 

AV SECOND FLOOR ROOM 22 

01-JUN-15

NORMAL 

NORMAL

T1-2-4 

AO FIRST FLOOR ROOM 17 

01-JUN-15

N/A 

UNSUPP

T1-2-7 

AO FIRST FLOOR ROOM 12 

12-MAY-15

N/A 

UNSUPP

T8-3-43 

AV SECOND FLOOR ROOM 25 

12-MAY-15

UNSUPP 

UNSUPP

TRUEALERT_ES SELF-TEST REPORT COMPLETED 

 

 

 

 

Press RETURN for next Screen OR CTRL-X to abort 

 

 

CUSTOM LABEL 

 

4-1-2 AV 
POINT ADDRESS: 4-1-2 

Type: AV 

CARD: 4     CHANNEL: 1    DEVICE: 2 
EXTENDED POWER SUPPLY 
UNIT NUMBER: 2 

RUI NUMBER: LOCAL 

PRIMARY STATUS 

NORMAL 

AUDIBLE GROUP CONFIG: 

0 0 0 

VISUAL GROUP CONFIG:  

0 0 0  

STYLE:  

INDOOR 

OPERATION:  

GENERAL EVAC 

CANDELA RATING 

15 CD 

COLOR LENS 

YES 

TONE TYPE 

BROADBAND 

CODING TYPE 

TEMPORAL 

VOLUME HIGH 
LAST TEST TIME: 

MON 01-JUN-15  01:00 AM 

LAST VISUAL TEST: 

NORMAL 

LAST AUDIBLE TEST: 

NORMAL 

LAST TEST VOLUME: 

NORMAL 

DEVICE TEST TROUBLE:  

NORMAL 

 TrueAlert ES Appliance Self-Test Last Test Results Report Example 

 TrueAlert ES Appliance Self-Test All Test Results Report Example 

 TrueAlert ES Appliance Self-Test Individual Appliance Report Example 

Содержание 4007-9201

Страница 1: ...on board memory to allow easy selection of desired revision An internal Ethernet service port and an internal serial service port are available for service computer connections to perform configuratio...

Страница 2: ...puter or to the USB drive Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring WALKTEST silent or audible system test performs an...

Страница 3: ...in Menu May 27 2015 12 24 PM System Trouble Screen identifies active troubles with custom labels displayed arrows allow navigation through the list Trouble Log Screen allows review of past troubles wi...

Страница 4: ...data sheet S4098 0052 for details TrueAlarm heat sensors can be selected for fixed temperature detection with or without rate of rise detection Utility temperature sensing is also available typically...

Страница 5: ...area zone covered by appliances on the notification appliance circuit NAC making it much more difficult and costly to locate and correct the source of a problem Using the TrueAlert magnet test allows...

Страница 6: ...num Models with BA are available assembled in the USA by adding the suffix BA 6 S4007 0002 6 11 2015 Factory Programming Options Model Description 4007 8810 Factory Programming select 4007 0831 Custom...

Страница 7: ...tion Manual 579 1103 4007ES Hybrid Data Sheet S4007 0001 Detailed Operator s Manual 579 1165 Field Installed Optional Modules Model Description Supv Alarm 4190 8001 TrueInsight Remote Service Gateway...

Страница 8: ...9803 IDNet Loop Expansion Modules maximum of two two are shown 4 IDNAC Power Supply Assembly 5 Location for additional 4007 9801 Zone Relay Module 6 Location for additional 4007 9801 Zone Relay Module...

Страница 9: ...009 IDNet NAC Extender S4009 0002 Battery and Battery Cabinet Reference S2081 0006 4003EC Voice Control Panel S4003 0002 Seismic Battery Brackets Reference S2081 0019 4606 Series Color LCD Touchscreen...

Страница 10: ...f Test TrueAlert addressable appliance not TrueAlert ES addressable appliance Note Additional TrueAlert ES Self Test information is detailed in Operating Instructions 579 1165 shipped with the panel S...

Отзывы: