Step 6:
Select option 2 at the Freeway Boot System Main Menu (
Figure 3–1 on page 49
) to
review the current boot parameters. Verify that the changes you entered are correct. If
the changes are incorrect, or you entered
nn
n
noo
o
o
to store data, select option 3 again and
modify the boot parameters to their correct values.
Step 7:
Select option 1 from the Freeway Boot System Main Menu (
Figure 3–1 on page 49
) on
the Freeway console to perform the system boot.
Note
You must perform the initial Freeway system boot from the local
console for Freeway to activate the Interactive Menu. After the ini-
tial system boot, you can telnet or rlogin to Freeway from the boot
server (or from any other computer on the network) and use the
Freeway Interactive Menu for Freeway operations as described in
the
Freeway User’s Guide
.
Note the four LEDs in the lower left corner of the front panel. If your Freeway has an
MVME 2600 CPU board, these LEDs are not used. However, if your Freeway has an
MVME 162 CPU board, these LEDs are used as diagnostic indicators. The LEDs turn
red briefly on power up or reset. The CPU then executes self-tests. At the start of the
selftests, LEDs 3 and 4 turn green immediately, while LEDs 1 and 2 remain red briefly,
then also turn green. All four LEDs remain green during the CPU selftests which last
about two minutes. Note that during the CPU selftests, the “FAIL” LED on the CPU
board itself turns red and remains red throughout most of the selftests.
When the CPU selftests complete, the Freeway boot test begins.
Содержание Freeway 2000
Страница 8: ...8 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 14: ...14 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 20: ...20 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 24: ...24 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 28: ...28 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 30: ...30 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 46: ...46 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 78: ...78 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 84: ...84 DC 900 1331F Freeway 2000 4000 Hardware Installation Guide ...
Страница 86: ...Simpact Inc Customer Service 9210 Sky Park Court San Diego CA 92123 ...