Fastening
Escutcheon fastening
with (optional) mech-
anical over-locking
Variant A0 (vertical
installation) [
Variants A1 and A2
(suspended
mounting) [
DS variant (reader
on both sides)
Variants E0 and E1
(Scandinavian Oval)
[
You fix the SI.Smart-
Handle AX with drill
holes and holes in the
mortise lock.
Mortise frame fastening
with (optional) mech-
anical overlocking
You fix the SI.Smart-
Handle AX on adapter
plates. These adapter
plates are screwed to
the metal frame using
rivet nuts.
Escutcheon fastening
with panic bar adapter
You fix the SI.Smart-
Handle AX by means of
adapter plates through
drilled holes and holes
in the mortise lock. On
the inside, you can then
mount a panic bar,
which must be ordered
separately.
6.4 Distances and door thicknesses
A* = Euro profile, B* = Swiss round, E* = Scandinavian Oval
Versions
Centres distance
Door thickness
A0/B0
Stationary
not relevant (stationary
installation: Handle
shaft axis and profile
cylinder axis not con-
nected at the fitting)
S: 38 - 60 mm
M: 59 - 80 mm
L: 79 - 100 mm
X: 100–200 mm
A1/B1
Suspended, short
70 - 79 mm
S: 38 - 60 mm
M: 59 - 80 mm
L: 79 - 100 mm
X: 100–200 mm
SmartHandle AX
SmartIntego
(Manual)
6. Versions
13 / 165
Содержание SI.SmartHandle AX A0
Страница 1: ...SmartHandle AX SmartIntego Manual 28 10 2020...
Страница 23: ...1 Pull out the mortise lock SmartHandle AX SmartIntego Manual 7 Installation 23 165...
Страница 37: ...SmartHandle AX SmartIntego Manual 7 Installation 37 165...
Страница 46: ...7 3 3 Procedure Preparing drill holes SmartHandle AX SmartIntego Manual 7 Installation 46 165...
Страница 47: ...1 Pull out the mortise lock SmartHandle AX SmartIntego Manual 7 Installation 47 165...
Страница 65: ...SmartHandle AX SmartIntego Manual 7 Installation 65 165...
Страница 68: ...7 4 3 Procedure Preparing drill holes SmartHandle AX SmartIntego Manual 7 Installation 68 165...
Страница 75: ...3 Insert the fitting into the adapter plate SmartHandle AX SmartIntego Manual 7 Installation 75 165...
Страница 76: ...4 Slide the fitting down as far as it will go SmartHandle AX SmartIntego Manual 7 Installation 76 165...
Страница 85: ...7 5 4 Procedure BKS Preparing drill holes SmartHandle AX SmartIntego Manual 7 Installation 85 165...
Страница 95: ...SmartHandle AX SmartIntego Manual 7 Installation 95 165...
Страница 107: ...2 Tighten the CISA mount with the centre mounting screw SmartHandle AX SmartIntego Manual 7 Installation 107 165...
Страница 129: ...8 Programming See TechGuide WO SVCN SmartHandle AX SmartIntego Manual 8 Programming 129 165...
Страница 130: ...9 Configuration See TechGuide WO SVCN SmartHandle AX SmartIntego Manual 9 Configuration 130 165...
Страница 131: ...10 Status messages See TechGuide WO SVCN SmartHandle AX SmartIntego Manual 10 Status messages 131 165...
Страница 132: ...11 Signal See TechGuide WO SVCN SmartHandle AX SmartIntego Manual 11 Signal 132 165...
Страница 158: ...Fig 2 Dimensioning SmartHandle AX suspended A1 A2 SmartHandle AX SmartIntego Manual 17 Technical specifications 158 165...
Страница 159: ...Fig 3 Dimensioning SmartHandle AX stationary A0 SmartHandle AX SmartIntego Manual 17 Technical specifications 159 165...
Страница 161: ...Fig 5 Dimensioning SmartHandle AX metal frame A3 SmartHandle AX SmartIntego Manual 17 Technical specifications 161 165...
Страница 162: ...Fig 6 Dimensioning SmartHandle AX BSL DS SmartHandle AX SmartIntego Manual 17 Technical specifications 162 165...