IMPORTANT

Take voltage drop into account

The resistance in copper produces a voltage drop, the size of which de-
pends on the cable gauge, current flow and cable length. The power supply
lines must be adequately dimensioned.

1. Ensure that the cable gauge in lines is adequate for power supply. Use

another suitable cable where necessary.

2. If required, merge wire pairs to increase the cable gauge.

3. Use a power source located closer to the SmartOutput module if

needed.

4. If possible, increase the supply voltage (observe technical

specifications).

SOM + SREL3.ADV

 (Manual)

12. Technical specifications

24 / 27

Содержание SOM + SREL3.ADV

Страница 1: ...SOM SREL3 ADV Manual 27 07 2021...

Страница 2: ...10 7 Installation 11 8 Connections 12 9 Connection to the SmartRelay 15 9 1 Standard power supply unit connection 15 9 2 Connecting a fire alarm system emergency release 16 9 3 Circuit to prevent open...

Страница 3: ...14 Help and other information 26 SOM SREL3 ADV Manual Content 3 27...

Страница 4: ...y the product only when needed and only in the manner described in the documentation IMPORTANT Damage resulting from electrostatic discharge ESD This product contains electronic components that may be...

Страница 5: ...ects Do not use SimonsVoss products for any other purposes Different times for G2 locks The internal time unit of the G2 locks has a technical tolerance of up to 15 minutes per year Qualifications req...

Страница 6: ...cepts no liability for any damage caused by incorrect installation IMPORTANT You must observe the manufacturer s warranty and installation conditions if you use other manufacturers products with a Sma...

Страница 7: ...Tab Example Name of a displayed window Example Upper programme bar Example Entry in the expanded upper pro gramme bar Example Context menu entry Example Name of a drop down menu Example Selection opt...

Страница 8: ...can be activated for a programmable time interval This assignment profile is freely programmable in LSM This means that the SmartOutput module is suitable for functions such as Authorisation dependen...

Страница 9: ...modules can be operated with a power supply unit The power supply unit must be able to deliver a suitable output voltage recommended 12 VDC and provide sufficient current see Technical specifications...

Страница 10: ...wer supply with the wrong polarity the electronics will be damaged Observe the polarity 9 SmartOutput module rattles when the power supply is connected 9 SmartOutput module flashes red once every 16 s...

Страница 11: ...N rail 2 Switch off the power supply 3 Connect all cables see Connections 12 4 Switch on the power supply IMPORTANT Check polarity is correct 5 Use the LSM software to programme the controller see Pro...

Страница 12: ...ate unchecked due to the de creasing voltage When the supply voltage is applied the output does not activate until the module has fully initialised and relay contacts can no longer switch un checked 2...

Страница 13: ...ated as NO in software activated depending on authorisations 16 5a Relay 5 Potential free contact NC treated as NO in software activated depending on authorisations 17 6b Relay 6 Potential free contac...

Страница 14: ...quipped with a detachable bridge to K1 number 26 ex works 26 K1 AUX relay Potential free contact normally open con tact Contact is connected with K2 number 23 if coil is connected to power Equipped wi...

Страница 15: ...2 1 B1 A1 2 B2 A2 3 B3 A3 O4 O3 O2 O1 O I I1 I2 I3 C A B I I Out A K1 A K2 L N C A B I I Out A K1 A K2 C A B I I Out A K1 A K2 Power supply unit Controller of the SREL3 Advanced SOM SOM SOM 9 1 Stand...

Страница 16: ...t OUT to prevent actuators such as a buzzer or an electric strike from switching of their own accord if the power supply to the SmartOutput module is interrupted This ensures that actuators will not b...

Страница 17: ...N L K2 A K1 A Out I I B A C 5b 5a N L Actuator Power supply unit for SmartOutput module Power supply unit for actuator SmartOutput module SOM SREL3 ADV Manual 9 Connection to the SmartRelay 17 27...

Страница 18: ...on button 9 The Extended configuration window will open 4 Enter the number of modules 5 Click on the OK button 9 Window closes 6 Click on the Apply button 7 Click on the Exit button 8 Execute programm...

Страница 19: ...which an SREL3 ADV activates 10 5 Naming in the software The LSM software automatically issues names for modules when they are added based on the following convention SmartRelay name module address 0...

Страница 20: ...switching behaviour has been inverted Allow for a possible power supply failure if you invert the switching behaviour in outputs 1 Double click on the module entry in the matrix to open the properties...

Страница 21: ...olour RGB LED which indicates the SmartOutput module s status Lights up green every five seconds Communication with SmartRelay OK Lights up red every five seconds Communication with SmartRelay disrup...

Страница 22: ...ax current 150 mA Reverse voltage protection yes Ambient conditions Temperature range 0 C to 60 C operation 0 C to 70 C in storage 1 week Humidity Max 90 non condensing Interfaces RS485 Acts as an int...

Страница 23: ...tact type 1x NO Switching voltage in out puts Max 24 V Switching current in outputs Max 200 mA OUT switching current Max 1 A OUTPUT switch ing voltage Max 24 V OUTPUT switch ing power Max 1 VA OUT sw...

Страница 24: ...adequately dimensioned 1 Ensure that the cable gauge in lines is adequate for power supply Use another suitable cable where necessary 2 If required merge wire pairs to increase the cable gauge 3 Use...

Страница 25: ...2012 19 EU WEEE as well as the corresponding UK statutory 2013 3113 WEEE 2011 65 EU RoHS as well as the corresponding UK statutory 2012 No 3032 RoHS and regulation EG 1907 2006 EU REACH as well as the...

Страница 26: ...MOD SOM8 in the household waste Dispose of it at a collection point for electronic waste as per European Directive 2012 19 EU Take the packaging to an environmentally responsible recycling point Hotli...

Страница 27: ...sustainable thinking and action and heartfelt appreciation of employees and partners SimonsVoss is a company in the ALLEGION Group a globally active network in the security sector Allegion is represe...

Отзывы: