Module
Address
Module 8
7
Module 9
8
Module 10
9
Module 11
A
Module 12
B
Module 13
C
Module 14
D
Module 15
E
1. Press the sides of the transparent inlay together.
2. Remove the transparent inlay.
3. Use a screwdriver to configure the address as per the table.
4. Insert the transparent inlay again.
10.4 Setting the pulse length
The pulse length for SREL3.ADV modules is identical to the pulse length
configured in the controller (exception: pulse lengths < 3 s). It cannot be
set for modules which an SREL3.ADV activates.
10.5 Naming in the software
The LSM software automatically issues names for modules when they are
added based on the following convention: SmartRelay name + module
address (0 to F) + output number (1 to 8).
Example: Lift_Mod#0_Out#4
You can also change the name as you wish.
1. Double-click on the entry in the matrix to open the properties of the out-
put of which you wish to change the name.
2. Change to the [Door] tab.
3. Enter the new name.
4. Click on the Apply button.
5. Click on the Exit button.
9
The output has now been renamed.
10.6 Inverting outputs
You can invert the switching behaviour of outputs.
SOM + SREL3.ADV
(Manual)
10. Programming and configuration
19 / 27