A991556
11-
28-
2019 1/5
ENGLISH
The iO Motion sensor is a Z-Wave based Sensor. It will send radio signals to associated Z-Wave
devices within its Z-Wave network when it detects IR changes. It can be installed on a shelf, in
the corner of a room, anywhere on the wall, or even on the ceiling.
Z-WAVE SPECIFICATIONS
Technical characteristics
The actual range of the sensor can be influenced by environmental
conditions. Should false motion alarms be reported, check for any
moving objects within the sensor’s detection area, such as trees
blowing in the wind, cars passing by, windmills, etc. False motion
alarms may be caused by moving masses of air and heat as well. If the
device continues reporting false alarms, despite eliminating all of the
above-mentioned factors, install the device in another place.
MOTION SENSOR
IO
Place the sensor anywhere you want.
Screw on
the wall
Double-sided
mounting tape
3M
1
Download the Simon iO application. After creating the installation, go to “Devices” and click
on add device, which can be found at the top right of the application.
Press for three seconds on the inclusion button. The LED will blink intermittently.
BATTERY REPLACEMENT
The battery can last around two years under normal conditions. High temperatures, high humidity
or other poor conditions may shorten battery lifespan.
We recommend changing the battery promptly when low power indication occurs.
Remove the battery blocker.
3
4
5
Turn the cover counter clockwise and open it.
2
A
B
Inclusion
button
4.1
Download the Simon iO application.
Go to “Devices” and click on add device
SIMON, S.A.U.
Diputación, 390-392 / 08013 Barcelona
[email protected] Tel: (+34) 902109700
www.simonelectric.com
4.2
Close the cover and turn it clockwise.
6
KEYPAD USE & FEEDBACKS
EVENT
BUTTON
ACTION
DEVICE
STATUS
BATTERY
STATUS
LEDs
FEEDBACK
DEVICE
ACTION
Not pressed
Long press
(2s<t<30s)
Short press
(t<2s)
Long press
(t>30s)
Short press
(t<2s)
Long press
(2s<t<30s)
Not included on
Z-Wave network
Not included on
Z-Wave network
Included on
Z-Wave network
Included on
Z-Wave network
Normal
Normal
Normal
Normal
Waking up
device
Pressing the
button
Reset
default
Pressing the
button
Add/
Removing
device from
Z-wave
Network
The device wakes up
No feedback
LED blinks intermittently
every 600ms, 3 times
LED blinks intermittently
every 2 seconds, 3 times
LED turns on for 2.5 se-
conds and then turns OFF
LED blinks intermittently
every 2 seconds, 3 times
LED blinks intermittently
every 300ms
The device sends a Node
Info to include or exclude
from the Z-wave Network
Configurations are set to
default values, it sends a
“Device Reset Locally to
Z-Wave controller” and
excludes from current
Z-Wave network
LED blinks intermittently
every 200ms, 15 times
No feedback
This is a Z-Wave Plus® Product using the latest S2 Security Encryption. This product can be ope-
rated on any Z-Wave network with other Z-Wave certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to
increase the reliability of the network.
Z-WAVE COMPLIANCE
DESCRIPTION
SUPPORTED COMMAND CLASSES
COMMAND CLASS ASSOCIATION GROUP INFO
COMMAND CLASS ASSOCIATION V2
COMMAND CLASS BATTERY
COMMAND CLASS CONFIGURATION
COMMAND CLASS DEVICE RESET LOCALLY
COMMAND CLASS FIRMWARE UPDATE MD V3
COMMAND CLASS MANUFACTURER SPECIFIC V2
COMMAND CLASS NOTIFICATION V5
COMMAND CLASS POWERLEVEL
COMMAND CLASS SECURITY
COMMAND CLASS SECURITY 2
COMMAND CLASS SUPERVISION
COMMAND CLASS TRANSPORT SERVICE V2
COMMAND CLASS VERSION V2
COMMAND CLASS WAKE UP V2
COMMAND CLASS Z-WAVE+ INFO V2
Z-WAVE DEVICE SPECIFICATION
Device Type
NOTIFICATION SENSOR
Generic Device Type
Specific Device Type SPECIFIC_TYPE_
POWER_SWITCH_BINARY
Role Typ
REPORTING_SLEEPING_
SLAVE
ASSOCIATION GROUPS
CONFIGURATION
Wake Up - Wake Up Notification is transmitted:
- Once every 24h --> Wake_Up capabilities from 30min to 24h and default 24h.
- When user presses the button for 2sec<T<30sec and device is included.
WAKE UP
Number of Groups
Max. devices in Group
Actions
Number of Groups
Max. devices in Group
Actions
Group 1 General: Lifeline
5
1. Notification Report. Sensor will send Notification Report to the associated nodes when
Motion Sensor is removed and/or PIR is triggered.
2. Battery Report. Motion Sensor will send Battery Report when the battery level is low and
the battery report’s value is 0xFF.
3. Device Reset Locally Notification.
Group Control: Key01
5
1. Basic Set. Motion Sensor will send Basic Set to associated nodes when the PIR is triggered.
NAME
VALUE
82
83
84
85
86
87
1
1
1
1
1
1
MOTIONSENSOR’S SENSITIVITY
Motion Sensor Blind Time
The motion sensor can send a com-
mand to nodes associated with group
2when motion is triggered.
Value of Basic Set
Enable/Disable Shock Alarm
Enable/Disable Motion Alarm
Cancellation
1 to 8 (Default)
The higher the value, the more sensitive the PIR sensor.
Change the (ON or Enable) to 255 (0xFF) in all configurations with
available values of 0 (OFF or Disable) and 1 (ON or Enable).
0x00 --> to nodes associated with group 2 when motion alarm is
triggered and Send Basic set value = ON to nodes associated with
group 2 when motion alarm is cancelled.
0xFF --> to nodes associated with group 2 when motion alarm is
triggered and Send Basic set value = OFF to nodes associated with
group 2 when motion alarm is cancelled.
Change the (ON or Enable) to 255 (0xFF) in all configurations with
available values of 0 (OFF or Disable) and 1 (ON or Enable).
Change the valid values:
Value: 0 --> OFF.
Value: 255 (Default) --> ON.
Default 30sec.
SIZE
To ensure good transmission quality, keep away from sources of interference
such as metal surfaces, microwave ovens, hi-fi equipment, televisions, ballasts
or transformers. During the addition/registration process, the iO sensor should
be close to the iO Simon HUB PRO socket to avoid draining the battery.
INSTALLATION
100
0x343-039
2
YEARS
under normal
condition
1
LED
x1
CR123A 3V
or USB
Ø 50mm
POWER SUPPLY
DIMENSIONS
BATTERY LIFE
INDICATORS
For more information on the EU Declaration of
Conformity and
Z-Wave
™
frequencies, consult the