User manual - METER SRT-N118-XA
4.2.
ASSEMBLY
- Disconnect the power supply prior to starting assembly.
- Check the connections are wired correctly prior to switching the unit on.
To install device on the wall, a pinholes should be made. Figure 4.1 presents
dimensions of the device and distances between holes. The back side of the device
has four mounting holes. This part of the case should be mounted to a wall by
screws.
Figure 4.1. Device and assembly dimensions
4.3.
CONNECTION METHOD
Caution
- Installation should be conducted by qualified personnel . During installation all
available safety requirements should be considered. The fitter is responsible for
executing the installation according to this manual, local safety and EMC
regulations.
- The unit is not equipped with an internal fuse or power supply circuit breaker.
Because of this an external time-delay cut-out fuse with a small nominal current
value must be used (recommended bipolar, max. 2A) and a power supply circuit-
breaker located near the unit. In the case of using a monopolar fuse it must be
mounted on the phase cable (L).
- The power supply network cable diameter must be selected in such a way that in
the case of a short circuit of the cable from the side of the unit the cable shall be
protected against destruction with an electrical installation fuse.
- Wiring must meet appropriate standards and local regulations and laws.
8
!
!
!
110 mm
80
m
m
67 mm
90 mm
60
m
m
ø8.4
ø4
.4