User manual - MODULE SLI-8
The answer (the same as the message):
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
20
00
02
09
C1
3. Reading of lower word of counter 4
ADDR
FUNC
REG H,L
COUNT H,L
CRC L,H
01
03
00
08
00
01
05
C8
The answer:
ADDR
FUNC
BYTE C
DATA H,L
CRC L,H
01
03
02
E4
1D
33
4D
DATA H, L - counter's no.4 content equals E41Dh = 58397
4. Simultaneous zeroing of all counters in all SLI-8 modules connected to the
network
ADDR
FUNC
REG H,L
COUNT H,L
CRC L,H
00
06
00
11
00
00
D8
1E
The answer:
Device doesn't send the answer because of 00h value in the address field
(BROADCAST type message).
5. Simultaneous zeroing of all counters in SLI-8 with address 01h
ADDR
FUNC
REG H,L
COUNT H,L
CRC L,H
01
06
00
11
00
00
D9
CF
The answer (the same as the message):
ADDR
FUNC
REG H,L
COUNT H,L
CRC L,H
01
06
00
11
00
00
D9
CF
6. Zeroing of counter no. 2 in SLI-8 module with address 01h
ADDR
FUNC
REG H,L
COUNT H,L
CRC L,H
01
06
00
03
00
00
79
CA