4. 

   DEVICE INSTALLATION

 

 

The unit has been designed and manufactured in a way assuring a high level of user  

safety and resistance to interference occurring in a typical industrial environment. In order to  

take full advantage of these characteristics installation of the unit must be conducted correctly  

and according to the local regulations.

- Read the basic safety requirements on page  2 prior to starting the installation.

-  Ensure that the power supply network voltage corresponds to the nominal  

voltage stated on the unit’s identification label.

- The load must correspond to the requirements listed in the technical data.

- All installation works must be conducted with a disconnected power supply.

- Protecting the power supply clamps against unauthorized persons must be  

taken into consideration.

4.1. 

 

 UNPACKING

 

 

After removing the unit from the protective packaging, check for transportation damage. Any  

transportation damage must be immediately reported to the carrier. Also, write down the unit  

serial number on the housing and report the damage to the manufacturer.

Attached with the unit please find:

- user’s manual,

- warranty,

- accessories.

4.2. 

 

 ASSEMBLY

 

 

-   The   unit   is   designed   for   mounting   indoor   inside   housings   (control   panel,  

switchboard)   assuring   appropriate   protection   against   electric   impulse   waves.  

Metal housing must be connected to the grounding in a way complying with the  

governing regulations. 

- Disconnect the power supply prior to starting assembly.

- Check the correctness of the performed connections prior to switching the unit on.  

In order to assembly the unit, a 45 x 22,2 mm mounting hole (Figure  4.1) must be 

prepared. Then follow the instructions  mentioned below (Figure 4.2):

1.  Insert gasket into the unit.

2.  Insert the unit into the panel. Use the correct panel cut-out size.

3.  Insert the mounting clip to the back of the unit.

4.  Push the mounting clip until it locks the unit tightly against the panel.

5

Содержание SLE-42

Страница 1: ...v 1 00 Type of input contact OC or voltage Self powered 3 6V 1 2AA Lithium Battery Read the user s manual carefully before starting to use the unit or software Please keep this manual for future refe...

Страница 2: ...te installation not maintaining the proper technical condition and using the unit against its destination Installation should be conducted by qualified personnel During installation all available safe...

Страница 3: ...side the control box does not exceed the recommended values In such cases forced cooling of the unit must be considered e g by using a ventilator The unit is designed for operation in an industrial en...

Страница 4: ...protection IP 54 Wiring M3 terminal screw Housing type Housing dimensions Panel cut size Weight panel 48 x 24 x 39 7 mm 45 x 22 2 mm 1 mm approx 50 g battery included Operating temperature Storage tem...

Страница 5: ...he unit from the protective packaging check for transportation damage Any transportation damage must be immediately reported to the carrier Also write down the unit serial number on the housing and re...

Страница 6: ...User manual for electronic counters SLE 42 and STH 42 Figure 4 1 Panel cut out dimensions Figure 4 2 Installing of clip and gasket Figure 4 3 Dimensions of the case 6 Mounting Clip Panel Gasket...

Страница 7: ...able shall be protected against destruction with an electrical installation fuse Wiring must meet appropriate standards and local regulations and laws In order to secure against accidental short circu...

Страница 8: ...small amount of detergent or in the case of more significant contamination ethyl or isopropyl alcohol Using any other agents can cause permanent damage to the housing Product marked with this symbol...

Страница 9: ...ain body Warning This unit uses Lithium battery Properly dispose the battery after use Do not short the positive and negative terminals recharge disassemble deform or dispose the battery to fire as th...

Страница 10: ...User manual for electronic counters SLE 42 and STH 42 6 PRINCIPLE OF OPERATION a b Figure 6 1 The counting principle of the SLE 42 counters a dry contact OC NPN input b wide range voltage input 10...

Страница 11: ...User manual for electronic counters SLE 42 and STH 42 11...

Страница 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Отзывы: