User manual for electronic counters SLE-42 and STH-42

-

 Do not attempt to disassemble, repair or modify the unit yourself. The unit  

has no user serviceable parts. Units, in which a defect was stated must be  
disconnected and submitted for repairs at an authorized service centre.

- In order to minimize fire or electric shock hazard, the unit must be protected  

against atmospheric precipitation and excessive humidity.

- Do not use the unit in areas threatened with excessive shocks, vibrations, dust,  

humidity, corrosive gasses and oils.

- Do not use the unit in explosion hazard areas.

- Do not use the unit in areas with significant temperature variations, exposed to  

condensation or icing.

- Do not use the unit in areas exposed to direct sunlight. 

- Make sure that the ambient temperature (e.g. inside the control box) does not  

exceed the recommended values. In such cases forced cooling of the unit must  

be considered (e.g. by using a ventilator).

The unit is designed for operation in an industrial environment and must  
not be used in a household environment or similar. 

2. 

   GENERAL CHARACTERISTICS

 

 

The   electronic   counters   are   popular,   self-powered   LCD   totalizers   (

SLE-42

)   or  hour 

meters (

STH-42

) in a small form. With a panel size of DIN 48 x 24 mm, they are perfect for  

limited   space   installations.   They   are   powered   by   a   replaceable   lithium   battery   that   lasts  

approximately 7 years, no external power required. They are available in 7 digits with 8 mm  

height figures with front reset or remote reset options. Input signal includes dry contact, open  

collector, voltage, wide range voltage at maximum count speed up to 30 Hz. The front panel  

protection is IP 54 and wiring connection is easily done via the terminal block  connector,  

making it secure and reliable. CE, UL and RoHS compliant.

3

Содержание SLE-42

Страница 1: ...v 1 00 Type of input contact OC or voltage Self powered 3 6V 1 2AA Lithium Battery Read the user s manual carefully before starting to use the unit or software Please keep this manual for future refe...

Страница 2: ...te installation not maintaining the proper technical condition and using the unit against its destination Installation should be conducted by qualified personnel During installation all available safe...

Страница 3: ...side the control box does not exceed the recommended values In such cases forced cooling of the unit must be considered e g by using a ventilator The unit is designed for operation in an industrial en...

Страница 4: ...protection IP 54 Wiring M3 terminal screw Housing type Housing dimensions Panel cut size Weight panel 48 x 24 x 39 7 mm 45 x 22 2 mm 1 mm approx 50 g battery included Operating temperature Storage tem...

Страница 5: ...he unit from the protective packaging check for transportation damage Any transportation damage must be immediately reported to the carrier Also write down the unit serial number on the housing and re...

Страница 6: ...User manual for electronic counters SLE 42 and STH 42 Figure 4 1 Panel cut out dimensions Figure 4 2 Installing of clip and gasket Figure 4 3 Dimensions of the case 6 Mounting Clip Panel Gasket...

Страница 7: ...able shall be protected against destruction with an electrical installation fuse Wiring must meet appropriate standards and local regulations and laws In order to secure against accidental short circu...

Страница 8: ...small amount of detergent or in the case of more significant contamination ethyl or isopropyl alcohol Using any other agents can cause permanent damage to the housing Product marked with this symbol...

Страница 9: ...ain body Warning This unit uses Lithium battery Properly dispose the battery after use Do not short the positive and negative terminals recharge disassemble deform or dispose the battery to fire as th...

Страница 10: ...User manual for electronic counters SLE 42 and STH 42 6 PRINCIPLE OF OPERATION a b Figure 6 1 The counting principle of the SLE 42 counters a dry contact OC NPN input b wide range voltage input 10...

Страница 11: ...User manual for electronic counters SLE 42 and STH 42 11...

Страница 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Отзывы: