Installation
Figure 5
SA. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit.
The circuit must be grounded and should be
dedicated to the sump pump.
5B. The pump is supplied with a 3-wire cord set
with grounding-type plug. Plug the switch
directly into the outlet and plug the pump into
the opposite end of the switch's plug.
I
A
WARNING
I
Risk of electric shock.
Can shock,
burn or kill. Always ground the pump to a suitable
electrical ground, such as a grounded water pipe,
a properly grounded metallic raceway, or a ground
wire system. Do not cut off the round ground pin.
Figure 6
6A. After you have installed the piping, check
valve, and float switch, the pump is ready for
operation.
4
6B. Check the pump by filling the sump with water
and observing the pump's operation through
one complete cycle. For switch settings see the
Electrical and Switch Specifications chart.
I
A
CAUTION
I
Risk of flooding.
Can cause
personal injury and/or property damage.
Failure to make this operational check may lead
to improper operation, premature failure, and
flooding.
For parts or assistance, call Simer Customer Service at 800-468-786 7
.