46
F4A
2.6.2 Wiring diagram (fig. 6)
“RMG 70-80-90-100 Mk.II” models
TS
EV2
R
ER
EA
EV1
N
N
230 V - 50 Hz-69 W
1
2
3
A
L
N 3
4
5
6
7
8
B
TA
IG
L
N
11
21
22
12
24
14
TC
TF
4
2
3
1
FA
9 10 11 12
14
13
16
15
17
22
21
20
19
18
23 24
L
N
PBY
TM
F
110
-110
230
0
TI
J6
J5
ION
JT
1
JT
2
N
1
2
3
4
5
6
7
16
17
18
19
J1
J4
T
TS
RESET
F4
A
VG2
L
AC
C
13
14
15
J3
VG1
U
U
N
L
CO
“RMG 110 Mk.II” models
CONNECTOR.SPARE.PART.CODES:
J1 code.6325662
J3 code.6293512
J4 code.6325661
CONNECTOR.SPARE.PART.CODES:
J1 code.6293511
J3 code.6293512
J4 code.6293510
KEY
IG.
Main.switch
TC.
Regulation.stat.with.
.
double.contact
EA. Ignition.electrode
EV2. Gas.valve.coil
EV1. Gas.valve.coil
TA.
Room.stat
R.
Lock.out.reset.button.
B.
Coil.assembly
ER. Sensing.electrode
TS.
Safety.stat
A.
Control.box
TF.
Smoke.stat
FA. EMC.filter
F.
Fuse.(T.200mA)
PBY. By-pass.pump
TI.
Isolated.transformer.
.
(only.for.FR/BE)
TM. Minimum.temperature.stat
CO. Hour.counter
NO TE: When connecting the TA remove
the jumper from terminals 6-7.
Fig..6
Содержание RMG 100 Mk.II