– Connect the pipe (5) code 6277824 to the connection (U-Do-
mestic hot water output) of the fitting template and to the boil-
er connection (U-DHW output)
– Connect the pipe (6) code 6226973 to the connection (G-Gas) of
the fitting template and to the boiler connection (G-gas)
– Connect the pipe (7) code 6277832 to the connection (E-ACS
inlet) of the boiler and the domestic hot water storage tank
5
U
G
7
6
Fig. 15
– Connect the pipe (8) code 6277828 to the plate heat exchanger
(Sp)
– Connect pipe (9) code 6277830 to the pipe (8) connection and
to the connection (MP- Heat Pump Delivery) of the fitting tem-
plate
– Connect the pipe (10) code 6277825 to the plate heat exchang-
er (Sp) and to the diverter valve (VD)
m
WARNING
Respect the direction of the diverter valve as shown
in the figure below
VD
11
12
B
A
AB
10
Fig. 16
– Connect the pipe (11) code 6277827 to the diverter valve (VD)
– Connect the pipe (12) code 6277826 to the diverter valve (VD)
and to the connection (RP-Heat Pump Return)
Rp Mp
8
10
12
11
VD
9
Fig. 17