42
3.5.7 Energy Settings
PARAMETERS MENU
GENERAL SETTINGS
GENERATION
I/O CONFIGURATION
HEATING
COOLING
DOMESTIC HOT WATER
ENERGY SETTINGS
Press
to access the energy settings.
Electrical-primary energy conversion factor
ENERGY SETTINGS
S700
ELECTRICAL-PRIMARY
ENERGY
CONVERSION FACTOR:
36%
PAR.
DESCRIPTION
RANGE
7000
Electrical-primary energy conversion
factor [%]
·
0 - 100
This is the transfer/generation output value (at point of de-
livery) of the electrical energy starting from the main energy
source (TOE, Tonne of Oil Equivalent).
Convenience type
ENERGY SETTINGS
S703
CONVENIENCE TYPE:
COST
PAR.
DESCRIPTION
RANGE
7030
Convenience type
·
Energy
·
Cost
Convenience type selection: Energy or Cost
Energy costs
ENERGY SETTINGS
S705
BOILER COSTS
Gas Type : METHANE
Pci Gas :
9460Wh/mc
Gas Cost : 85Ecent/kWh
HEAT PUMP COSTS
El. Cost : 25Ecent/kWh
PAR.
DESCRIPTION
RANGE
7050
Boiler Gas Type
·
Methane
·
Gpl
7054
Cost of Methane Gas
·
0 - 999
7055
Cost of GPL Gas
·
0 - 999
7058
Cost of Electricity
·
0 - 999
Setting boiler costs: Gas type, Lower heat output (only with
manufacturer's password), Gas Cost
Setting heat pump costs: Cost of electricity.
Photovoltaic function
ENERGY SETTINGS
S710
PHOTOVOLTAIC SYSTEM
NOT INCLUDED
Power peak
: 03.0kWp
Fixed consumpt : 01.0kWp
HP Heat Output
: 09kW
PAR.
DESCRIPTION
RANGE
7100
Photovoltaic System Included
·
Not included
·
Included
7104
Photovoltaic System Peak Power
·
0.0 - 99.9
7106
Fixed Residential Building Consump-
tion
·
0.0 - 99.9
7109
Heat Pump Nominal Heat Output
·
1 - 32
Photovoltaic function only available if there is a solar thermal
energy kit.
By setting PHOTOVOLTAIC SYSTEM INCLUDED and entering
the peak power, fixed consumption values of the building (tak-
ing into account at least one electrical appliance in operation)
and the nominal heat output of the heat pump, this function
estimates the electrical power produced by the photovoltaic
system (using the solar kit sensors). It then reduces the cost
of electricity in relation to the share of energy available from
the photovoltaic system, therefore raising the share of con-
sumption of electricity produced by the photovoltaic system.
Minimum external temperature for Heat Pump convenience
ENERGY SETTINGS
S722
MINIMUM EXTERNAL
TEMPERATURE FOR HEAT
PUMP CONVENIENCE:
-15.0ºc
PAR.
DESCRIPTION
RANGE
7220
Minimum external temperature for Heat
Pump convenience [°C]
·
-50.0 - 50.0
Minimum external temperature below which the Heat Pump is
always considered not convenient.
Содержание Open Hybrid MEM 25-006