99
ES
PT
ENG
2.10
SUPPLEMENTARY SOURCE
PRESENCE FUNCTION
This function is typically used in multi-
energy systems, in which, for outside
temperatures greater than a set value,
the C.H. loads are met exclusively from
an alternative source to the boiler.
This function has the purpose of making
the boiler intervene, in the case of a C.H.
request, only if the outdoor temperatu-
re falls below the threshold. The boiler
however remains on stand-by in the
event of D.H.W. request.
To activate the function set PAR 34 INST
by entering the value of the outside tem-
perature above which the burner stays
off and the C.H. requests are met by a
supplementary source. Also by setting
PAR 5 = 5, during a C.H. request the
auxiliary relay used for the intervention
of the supplementary source is activated,
typically a heat pump. The remote alarm
output of the alternative source may be
placed in parallel to the external probe
so that in the event of failure of the sup-
plementary source, the boiler remains
however the only one to meet the loads.
ALLARME
(SE PRESENTE)
ON/OFF
POMPA DI CALORE
PUFFER
POMPE DI ZONA
SCHEDA CALDAIA
SONDA ESTERNA
EXTERNAL PROBE
BOILER BOARD
PUFFER
ZONE
PUMPS
HEAT PUMP
ALARMS (if present)
ON/OFF
S1
SB
R
M
SE
TA1
SE
SI
P1
TA2
EXP
VM
EXP
IP
TA1
TA2
P2
VM
EXP
EXP (INSOL)
Murelle HM T/HE T-R ErP
S2
CR
CR
P3
(CR)
(TA2)
(TA1)
VENTILCONVETTORE
R
M
SE
TA1
SE
SI
P1
TA2
EXP
VM
EXP
IP
TA1
TA2
P2
VM
IP
EXP
13
SYSTEM WITH MIXER VALVE
SYSTEM WITH TWO MIXED ZONES INDEPENDENT, TWO KITS ZONA MIX (Code 8092234) AND EXTERNAL
SENSOR (supplied with)
14
SYSTEM SOLAR
SYSTEM WITH TWO MIXED ZONES INDEPENDENT, ONE DIRECT ZONE, WO KITS ZONA MIX (Code 8092234), ONE
KIT SOLAR INSOL (Code 8092235), REMOTE CONTROL SIME HOME (Code 8092280/81) AND
EXTERNAL SENSOR
(supplied with)
FAN COIL