97
ES
PT
ENG
3.3
ACCESS TO
INSTALLER’S
PARAMETERS
For.access.to.the.installer’s.parameters,.
press. simultaneously. the. keys
.
5
3
1
2
4
.
and
.
5
3
1
2
4
.
or.5.seconds.(3.fig..12).
..
For. example,. the. parameter. PAR. 23. is.
visualised. on. the. display. of. the. control.
panel.in.the.following.way:
The. parameters. scroll. forwards. and.
backwards.with.the.key
.
5
3
1
2
4
.
and
.
5
3
1
2
4
and.
the. default. parameters. can. be. changed.
with.the.keys
.
5
3
1
2
4
.
and
.
5
3
1
2
4
.
.
The.standard.visualisation.returns.auto-
matically. after. 60. seconds,. or. by. pres-
sing.one.of.the.control.keys.(2.fig..12).
3.3.1 Replacing the board or
RESETTING parameters
If. the. electronic. board. is. replaced. or.
reset,.it.is.necessary.to.configure.PAR.1.
and. PAR. 2. by. associating. the. following.
values.to.each.type.of.boiler.to.be.able.to.
restart.the.boiler:.
1.
.Visualizzazione.temperatura
.....esterna.solo.con.sonda.esterna.collegata
2...Visualizzazione.temperatura.sonda
.....riscaldamento.(SM)
3...Visualizzazione.temperatura.sonda
.....sanitario.(SS).solo.per.caldaie.istantanee
4. .Visualizzazione.temperatura.sonda
.....ausiliaria.o.sonda.bollitore.(SB)
6..Visualizzazione.temperatura
.....riscaldamento.riferita.al.primo.circuito
7..Visualizzazione.temperatura
.....riscaldamento.riferita.al.secondo.circuito
13...Visualizzazione.codice.errore
.......penultima.anomalia
14...Visualizzazione.numero.totale
.......delle.anomalie
9...Visualizzazione.numero.giri.ventilatore.in.rpm.x.100.(es..4.800.e.1.850.rpm)
10...Visualizzazione.ore.di.funzionamento.del.bruciatore.in.h.x.100.(es..14.000.e.10)
11...Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
12...Visualizzazione.codice.errore
.......ultima.anomalia
15...Contatore.accessi.parametri
.......installatore.(es..140.accessi)
5...Visualizzazione.temperatura
.....sonda.fumi
8...Visualizzazione.corrente
.....di.ionizzazione.in.µA
16...Contatore.accessi.parametri
.......OEM.(es..48.accessi)
PARAMETERS INSTALLER
FAST CONFIGURATION
PAR. DESCRIPTION...
RANGE.
UNIT.OF.
INC/DEC.. DEFAULT
.
.
.
MEASUREMENT. UNIT.
SETTING
.1
.
Combustion.configuration
.
--.=.ND.
=.
=.
“--”
.
.
1.....30
.
.
.
.2
.
Hydraulic.configuration
.
--.=.ND.
=.
=.
“--”
.
.
1.....9
..
.
1.=.DHW.+.Recirc..pump.
.3.
Timetable.2.programmer.
2.=.DHW.
=.
=.
1
.
.
3.=.Recirculation.pump
.4.
Pressure.transducer.disabler.
0.=.Disabled.
=.
=.
1
.
.
1.=.Enabled
.
.
2.=.Enabled.(NO.ALL.09)
.5.
Assignment.of.auxiliary.relay.AUX..
1.=.Remote.supply.
=.
=.
1
.
(D.H.W..tank).
2.=.Recirculation.pump.
.6.
Luminous.bar.indicating.presence.
0.=.Disabled.
=.
=.
1
.
of.voltage.
1.=.Enabled
...
.
0.=.Not.assigned
.
.7.
Allocation.of.SIME.HOME.channels.
.
1.=.Circuit.1.
=.
=.
1
.
.
2.=.Circuits.1.and.2
.
8.
Fan.rpm.Step.ignition.
0,0.....81.
rpmx100. 0,1da.0,1a19,9.
0,0
.
.
.
.
1da.20.a.81
.
9.
Long.chimneys.
0.....20.
%.
1.
0
...
.
1.=.SIME.HOME
.
.10. Remote.control.(CR).option.setting.
2.=.CR.53.
=.
=.
1
.
.
3.=.RVS
.11. Correction.values.external.sensor.
-5.....+5.
°C.
1.
0
..
.
--..=.Always
.
.12. Backlighting.duration.
0.=.Never.
sec..x.10.
1.
3
..
.
1.....199
.
..
.
0.=.Minimum
.
.13. Modulating.pump.speed.
1.=.Maximum.
=.
=.
1
..
.
2.=.Automatic
.
.
.
D.H.W. - HEATING
PAR. DESCRIPTION...
RANGE.
UNIT.OF.
INC/DEC.. DEFAULT
.
.
.
MEASUREMENT. UNIT.
SETTING
20. D.H.W..minimum.temperature.
10.°C.....PAR.21.
°C.
1.
30
21. D.H.W..maximum.temperature.
PAR.20.....PAR.62.OEM.
°C.
1.
60
22. Anti-legionella.(only.D.H.W..tank).
0.=.Disabled.
=.
=.
0
.
.
1.=.Enabled
23. Boiler.antifreeze.
0.....+20.
°C.
1.
3
24. External.sensor.antifreeze.
-.15.....+5.
°C.
1.
-.2
25. Climatic.curve.setting.Zone.1.
3.....40.
=.
1.
20
26. Climatic.curve.setting.Zone.2..
3.....40.
=.
1.
20
27. Minimum.temperature.Zone.1.
PAR.64.OEM.....PAR.28.
°C.
1.
20
28. Minimum.temperature.Zone.1.
PAR.27.....PAR.65.OEM.
°C.
1.
80
29. Minimum.temperature.Zone.2.
PAR.64.OEM.....PAR.30.
°C.
1.
20
30. Maximum.temperature.Zone.2.
PAR.29.....PAR.65.OEM.
°C.
1.
80
31. Maximum.heating.power.
30.....100.
%.
1.
100
32. C.H..post-circulation.time.
0.....199.
Sec..
10.
30
33. Pump.activation.delay.Zone.1.
0.....199.
10.sec..
1.
1
34. Re-ignition.delay.
0.....10.
Min..
1.
3
35. Integrative.sources.activation.threshold.. --.,.15.....80.
°C.
1.
“--”
36. D.H.W..post-circulation.time
.
0.....199
.
Sec..
1.
0
39. Saturation.zone.modulation.
.
--..=.Enabled.
%.
1.
100
.
D.H.W..flowmeter.
.
0.....100
GAS
MODELS
PAR 1
.
.
12.T.
1
. METHANE.
-.
2
.
(G20).
25.-.25.T.
3
.
.
30.-.30.T.
4
.
.
35.-35.T.
5
.
.
12.T.
6
.
.
-.
7
.
..
-.
8
. PROPANE.
25.-.25.T.
9
.
(G31).
-.
10
.
.
30.-.30.T.
11
.
.
35.-.35.T.
12
Содержание MURELLE EV HE 12 T
Страница 1: ...MURELLE HE ErP Fonderie SIME S p A Cod 6322859B 03 2017 ENG...
Страница 2: ......
Страница 47: ......