CHARACTERISTICS
3.1
CONTROL PANEL
5
3
1
2
4
2 - DESCRIPTION OF CONTROLS
5
3
1
2
4
ON/OFF KEYS
ON.=.. Electricity.supply.to.boiler.is.on
OFF.=..
Electricity. supply. to. boiler. is. on. but. nor.
ready. for. functioning.. However,. the. protec-
tion.functions.are.active.
5
3
1
2
4
SUMMER MODE KEY
When.this.key.is.pressed,.the.boiler.functions.only.
when.D.H.W..is.requested.
5
3
1
2
4
WINTER MODE KEY
When.this.key.is.pressed,.the.boiler.provides.hea-
ting.and.D.H.W.
5
3
1
2
4
D.H.W. TEMP KEY
When. this. key. is. pressed,. the. temperature. of. the.
D.H.W..is.shown.on.the.display.
5
3
1
2
4
HEATING TEMP KEY
The.first.time.the.key.is.pressed,.the.temperature.of.
heating.circuit.1.is.shown.
The.second.time.the.key.is.pressed,.the.temperatu-
re.of.heating.circuit.2.is.shown.
5
3
1
2
4
RE-SET KEY
This.allows.for.restoring.functioning.after.a.functio-
ning.anomaly.
5
3
1
2
4
INCREASE AND DECREASE KEY
By. pressing. this. key. the. set. value. increases. or.
decreases.
4 - LUMINOUS BAR
. Blue.=.Functioning
. Red.=.Functioning.anomaly
5 - PROGRAMMING CLOCK (optional)
Mechanical. clock. (code. 8092228). or. digital. clock.
(code.8092229).to.program.heating.and.water.supply.
Fig..12
3 - KEYS RESERVED FOR THE INSTALLER
(access to INST and OEM parameters)
PC CONNECTION
To.be.used.only.with.the.SIME.programming.kit.and.only.
by.authorised.personnel..Do.not.connect.other.electro-
nic.devices.(cameras,.telephones,.mp3.players,.etc.).Use.
a.tool.to.remove.the.cap.and.reinsert.after.use.
ATTENTION: Communication port
sensitive to electrostatic charges.
Before.use,.it.is.advisable.to.touch.an.
earthed.metallic.surface.to.discharge.static.electricity.
INFORMATION KEY
This. key. can. be. pressed. several. times. to. view. the.
parameters.
.
CHIMNEY SWEEP KEY
This. key. can. be. pressed. several. times. to. view. the.
parameters..
DECREASE KEY
This.key.changes.the.default.settings.
INCREASE KEY
This.key.changes.the.default.settings.
5
3
1
2
4
DESCRIPTION OF DISPLAY ICONS
SUMMER MODE ICON
WINTER MODE ICON
D.H.W. MODE ICON
HEATING MODE ICON
1.=.First.circuit.heating.system
2.=.Second.circuit.heating.system
GRADED POWER SCALE
The. segments. of. the. bar. light. up. in. proportion. to. boiler.
power.output..
BURNER FUNCTIONING AND BLOCK ICON
DESCRIPTION OF DISPLAY ICONS
CHIMNEY SWEEP ICON
SECONDARY DIGITS
The. boiler. visualises. the. value. of. the. pressure. of.
the.system.(correct.value.is.between.1.and.1.5.bar)
MAIN DIGITS
The.boiler.visualises.the.values.set,.the.state.
of.anomaly.and.the.external.temperature
INTEGRATIVE SOURCES ICON