106
3.9
FUMES PRESSURE SWITCH
vers. BF-BFT (fig. 16)
The pressure switch is calibrated by the
manufacturer at the following values:
5.3 - 6.3 H
2
O for vers.
“25 BF - 25 BFT”
3.6 - 4.6 H
2
O for vers.
“30 BF”
4.6 - 5.6 H
2
O for vers.
“20 BF - 35 BFT”
which can guarantee boiler functioning also
with aspiration and discharge pipes of the
maximum length allowed.
The value of the signal to the pressure swit-
ch is measured by a differential pressure
gauge connected as indicated in fig. 16.
3.10
HEAD AVAILABLE TO SYSTEM
(fig. 17)
Residual head for the heating system is
shown as a function of rate of flow in the
graph in fig. 17. The speed of the modula-
ting pump is set as default (installation
parameter
PAR 13=1
).
Fig. 16
0
600
200
1200
1000
800
600
400
PORTATA (l/h)
PREV
ALENZA RESIDU
A (mbar)
500
400
100
200
300
Mur
elle EV
25-30 OF
velocità max pompa
velocità min. pompa
20 BFT
25 BF/BFT/GG MT 25 PLUS
25 BF/BFT/GG MT 25 PLUS
30-35 BF /GG MT 30-35 PLUS
25-30 OF
Fig. 17
RESIDU
AL
HEAD (mbar)
FLOW RATE (l/h)